![Vaillant electronicVED plus Operating Instructions & Installation Instructions Download Page 16](http://html1.mh-extra.com/html/vaillant/electronicved-plus/electronicved-plus_operating-instructions-and-installation-instructions_3985700016.webp)
4 Set-up
14
Installation
instructions
electronicVED
plus
0020288449_01
3.4 CE marking
The CE marking shows that the products
comply with the basic requirements of the
applicable directives as stated on the de-
claration of conformity.
The declaration of conformity can be
viewed at the manufacturer's site.
4 Set-up
4.1 Checking the scope of delivery
Quantity Designation
1
Product
1
Operating and installation in-
structions
1
Bag containing fixing material
(2 bolts, 2 wall plugs, 3 seals, 1
special fixing screw)
1
G 1/2" cold water connector
with a cold-water isolation valve
1
G 1/2" domestic hot water con-
nector
2
Double nipple
1
Strainer for the cold water inlet
1
Mounting plate
1
Mounting template
4.2 Selecting an installation
location
▶
Install the product as close as possible
to the draw-off points that are used
most frequently.
Note
The product may also be in-
stalled above baths or in a
shower area.
4.3 Installation clearances
C
D
E
A
C
B
B
A
≥
50 mm
B
≥
50 mm
C
≥
120 mm
D
≥
130 mm
E
≤
22 mm
The bottom section of the product
(D)
must
be level with the product's bearing area on
the wall;.
4.4 Installing the product on the
wall
4.4.1 Dimensions
1
2
3
4
5
6
481
312
240
100
277
50
12
19
16
100
35
35
1
Top grommet
2
Central attach-
ment
3
G 1/2" domestic
hot water con-
nection
4
G 1/2" cold wa-
ter connection
5
Bottom grommet
6
G 1/2" outside
thread