Safety 1
0020258610_00 ecoVIT exclusiv Installation and maintenance instructions
5
1.3.10 Risk of material damage caused by
frost
▶
Do not install the product in rooms prone
to frost.
1.3.11 Risk of material damage caused by
using an unsuitable tool
▶
Use the correct tool to tighten or loosen
threaded connections.
1.3.12 Risk of poisoning and burns caused
by escaping hot flue gases
▶
Only operate the product if the air/flue pipe
has been completely installed.
▶
With the exception of short periods for
testing purposes, only operate the product
when the front casing is installed and
closed.
1.3.13 Risk of death due to lack of safety
devices
The schematic drawings included in this doc-
ument do not show all safety devices re-
quired for correct installation.
▶
Install the necessary safety devices in the
system.
▶
Observe the applicable national and inter-
national laws, standards and guidelines.
1.3.14 Risk of being burned or scalded by
hot components
▶
Only carry out work on these components
once they have cooled down.
1.3.15 Risk of death from escaping flue
gas
If you operate the product with an empty con-
densate siphon, flue gas may escape into the
room air.
▶
In order to operate the product, ensure that
the condensate siphon is always full.
Conditions
: Permitted B23 or B23P type
units with condensate siphon (third-party
accessory)
–
Water seal level:
≥
200 mm
1.3.16 Risk of scalding from hot potable
water
There is a risk of scalding at the domestic
hot water draw-off points if the domestic hot
water temperatures are greater than 60 °C.
Young children and elderly persons are par-
ticularly at risk, even at lower temperatures.
▶
Select a moderate set target temperature.
▶
Inform the end user about the risk of scald-
ing when the
Anti-legionella
function is
switched on.
1.4
Regulations (directives, laws,
standards)
▶
Observe the national regulations, stand-
ards, guidelines and laws.