background image

2

2

General information  . . . . . . . . . . . . . . . . . .

2

1.1

For your information  . . . . . . . . . . . . . . . . . . . . .

2

1.2

Key to symbols  . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.3

Liability  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2

1.4Specified use  . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

1.5

EC designation  . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Safety instructions  . . . . . . . . . . . . . . . . . . .

3

2.1

Setup and adjustments  . . . . . . . . . . . . . . . . . . .

3

2.2

Gas smell  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

2.3

Modifications in and around the boiler  . . . . . .

3

2.4Explosive and flammable materials  . . . . . . . . .

3

2.5

Inspection  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

3

Factory guarantee  . . . . . . . . . . . . . . . . . . . .

4

3.1

Your guarantee  . . . . . . . . . . . . . . . . . . . . . . . . .

4

3.2

Registering with us  . . . . . . . . . . . . . . . . . . . . . .

4

3.3

Immediate help  . . . . . . . . . . . . . . . . . . . . . . . . .

4

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

4.1

Overview  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

4

4.1.1

Operating controls  . . . . . . . . . . . . . . . . . . . . . . .

4

4.1.2

Advanced multifunctional system display  . . . .

5

4.2

Initial checks before turning ON  . . . . . . . . . . .

5

4.2.1

Opening the service valves  . . . . . . . . . . . . . . . .

5

4.2.2 Checking the water contents  . . . . . . . . . . . . . .

5

4.3

Domestic hot water operation  . . . . . . . . . . . . .

6

4.3.1

Setting the maximum domestic hot water 
temperature control (ecoMAX 800 series only)

6

4.3.2 Warmstart operation 

(ecoMAX 800 series only) . . . . . . . . . . . . . . . . .

6

4.3.3 Obtaining hot water (ecoMAX 800 series only)

7

4.4

Heating operation  . . . . . . . . . . . . . . . . . . . . . . .

7

4.4.1

Setting the maximum radiator temperature 
control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

7

4.4.2 Setting the external controls  . . . . . . . . . . . . . .

8

4.5

Status displays  . . . . . . . . . . . . . . . . . . . . . . . . . .

8

4.6

Resetting the appliance . . . . . . . . . . . . . . . . . . .

9

4.7

Turning the boiler OFF  . . . . . . . . . . . . . . . . . . .

10

4.7.1

To turn OFF the central heating only 
(Summer mode)  . . . . . . . . . . . . . . . . . . . . . . . . .

10

4.7.2 To turn OFF central heating and hot water 

for short periods of time . . . . . . . . . . . . . . . . . .

10

4.8

Turning the boiler OFF
(ecoMAX 600 series only) . . . . . . . . . . . . . . . . .

10

4.8.1 To turn OFF the central heating  . . . . . . . . . . . .

10

4.8.2 To turn boiler OFF for short periods of time  .

10

4.9

Troubleshooting  . . . . . . . . . . . . . . . . . . . . . . . . .

11

4.10

Care and maintenance  . . . . . . . . . . . . . . . . . . .

11

4.11

Frost-protection  . . . . . . . . . . . . . . . . . . . . . . . . .

11

1 General information

1.1 For your information

Thank you for choosing a Vaillant boiler. The information
given in this booklet will enable you to obtain the best
performance from your boiler.

ecoMAX 800 series

provides both central heating and

domestic hot water, with the domestic hot water 
supplied directly from the boiler. The boiler will operate
automatically to provide domestic hot water whenever a
hot water tap is opened, and automatically adjusts to
meet the demand for both central heating and domestic
hot water in the most economical way.

ecoMAX 600 series

provides central heating and

domestic hot water where a separate indirect hot water
cylinder is also incorporated to the system.

The benchmark gas boiler commissioning checklist (in
the installation manual) should be completed by the
installer and/or the commissioning engineer. 
All CORGI Registered Installers carry a CORGI ID card,
and have a registration number. Both should be recorded
in the Benchmark gas boiler commissioning checklist. 
You can check your installer by calling CORGI direct on
01256 372300.
If, after reading these instructions, you have any 
questions on the operation of the boiler, please contact
either your installer or Vaillant Technical Department.

1.2 Key to symbols

Attention!

Important Note 

Note!

This symbol is used to indicate important
instructions.

• This symbol is used to indicate a required step.

1.3 Liability

Attention!

We can accept no liability whatsoever for dama-
ge or injury resulting from failure to observe

these instructions.

Table of contents
1 General information

Instructions for use ecoMAX

834215_14GB_032005.qxd  09.03.2005 18:04 Uhr  Seite 2

Summary of Contents for ecoMAX SERIES

Page 1: ...For the user ecoMAX 613 2 E ecoMAX 618 2 E ecoMAX 622 2 E ecoMAX 635 E ecoMAX 824 2 E ecoMAX 828 2 E ecoMAX 835 E GB Instructions for use ecoMAX Wall hung room sealed fan assisted condensing boilers...

Page 2: ...n 11 1 General information 1 1 For your information Thank you for choosing a Vaillant boiler The information given in this booklet will enable you to obtain the best performance from your boiler ecoMA...

Page 3: ...stallation and adjustment of the boiler as well as servi ce maintenance and repair of the boiler may only be car ried out by a competent person in accordance with the Gas Safety Installation and Use R...

Page 4: ...nt is needed under the terms of our Guarantee If you are unable to contact your installer phone Vaillant Service Solutions 0870 6060 777 4 Operation 4 1 Overview 4 1 1 Operating controls For access to...

Page 5: ...urner is on Warmstart is on ecoMAX 800 series only Illuminated warmstart turned on Flashing warmstart demand burner is on Internal pump is running Gas valve is activated Flame crossed out Boiler is at...

Page 6: ...rature and anti clockwise to decrease the temperature Note This control adjusts the maximum domestic hot water temperature If adjusting the control upwards appears to have no effect on the tem peratur...

Page 7: ...or continues to operate for central heating if required The pump and fan will continue to operate for a short period 4 4 Heating operation The boiler should only be used when the heating system conta...

Page 8: ...he boiler for short periods when in the central heating mode When turning the room thermostat to a higher setting there may therefore be a short delay before the boiler operates 4 5 Status displays Fi...

Page 9: ...hold for approx 1 second Attention If the boiler still shuts off after a third attempt then please consult your installer or Vaillant Service Solutions The boiler also switches to Fault when there is...

Page 10: ...OFF for a longer period of time e g holidays and there is no danger of frost then you should also turn off the gas supply the cold water service valve see page 5 and the electrical supply Please note...

Page 11: ...ar servicing it is strongly recommended that arrangements are made with your service agent or Vaillant Ltd For further details please contact Vaillant Service Solutions 0870 6060777 4 11 Frost protect...

Page 12: ...834215_14 GB 03 2005 Subject to alteration...

Reviews: