Installation
6
ecoLEVEL installation and maintenance instructions 0020029316_01
3
3
Installation
3.1
Scope of delivery
Betriebs anleitung
Für den Betreiber
DE, AT, BEDE, CHDE
Betriebs anleitung
ecoLEVEL
Kondenswasserpumpe
1
2
3
4
5
6
8
7
9
10
3.1
Scope of delivery
Item Component
Dimensions
Number
1
Condensed water pump
(H x W x L)
150 x 175 x 100 mm
1
2
Fixing plugs
6 mm
2
3
Bolts
4 x 35 mm
2
4
Wall bracket
-
1
5
Drain hose
dia. 10 mm x 6 m
1
6
Installation and mainte-
nance instructions
-
1
7
Socket screw connection 15 x 22 mm
1
8
Stainless steel pipe
insert
-
1
9
Coupling piece
22 mm x 3/4" imperial
1
10
Inlet hose
dia. 24 mm x 1.15 m
1
Wall bracket for drain
hose
-
6
3.1 Scope of delivery
3.2 Required
tools
The following tools are required for installation:
– Drill
– Drill bit (6 mm)
– Flat blade screwdriver
– Spirit level
– Cutting blade
– Tools for electrical connection
3.3
Selecting the installation site
The ecoLEVEL condensed water pump is designed for
installation in the room housing the boiler.
The ambient temperature must be between 5 °C and 60 °C.
The condition of the walls in the installation room must
allow the connecting elements supplied to be used without
any problems.
>
If the walls are not in a suitable condition, a suitable
installation surface must be prepared before starting the
installation.
The ecoLEVEL condensed water pump must not be used as
a storage surface for objects.