1 Safety

1.1 Action-related warnings
Classification of action-re-
lated warnings

The action-related warnings
are classified in accordance
with the severity of the pos-
sible danger using the following
warning signs and signal words:

Warning symbols and signal
words

Danger!

Imminent danger to life
or risk of severe personal
injury

Danger!

Risk of death from electric
shock

Warning.

Risk of minor personal
injury

Caution.

Risk of material or envir-
onmental damage

1.2 Intended use

There is a risk of injury or death
to the user or others, or of dam-
age to the product and other
property in the event of im-
proper use or use for which it
is not intended.
The product is intended as a
heat generator for closed heat-

ing installations and for hot wa-
ter generation.
Intended use includes the fol-
lowing:

observance of the operating
instructions included for the
product and any other system
components

compliance with all inspection
and maintenance conditions
listed in the instructions.

This product can be used by
children aged from 8 years
and above and persons with
reduced physical, sensory or
mental capabilities or lack of
experience and knowledge if
they have been given supervi-
sion or instruction concerning
use of the product in a safe way
and understand the hazards in-
volved. Children must not play
with the product. Cleaning and
user maintenance work must
not be carried out by children
unless they are supervised.
Any other use that is not spe-
cified in these instructions, or
use beyond that specified in this
document shall be considered
improper use. Any direct com-
mercial or industrial use is also
deemed to be improper.

Caution.

Improper use of any kind is
prohibited.

Summary of Contents for ecoFIT pure 612

Page 1: ...Operating instructions ecoFIT pure 612 630 GB IE Operating instructions Publisher manufacturer Vaillant GmbH Berghauser Str 40 D 42859 Remscheid Tel 49 21 91 18 0 Fax 49 21 91 18 2810 info vaillant de...

Page 2: ...tching on the product 11 4 8 Setting the heating flow temperature 11 4 9 Setting the hot water temperature 11 4 10 Switching off the product s functions 11 4 11 Guaranteeing the correct filling pressu...

Page 3: ...t ing installations and for hot wa ter generation Intended use includes the fol lowing observance of the operating instructions included for the product and any other system components compliance with...

Page 4: ...rooms that smell of gas If possible open doors and windows fully and ensure adequate ventilation Do not use naked flames e g lighters matches Do not smoke Do not use any electrical switches mains plug...

Page 5: ...the expansion relief valve to the drain pipework to constructional condi tions that may affect the operational reliability of the product 1 3 7 Risk of corrosion damage due to unsuitable combustion a...

Page 6: ...ial damage due to maintenance and repairs carried out incorrectly or not carried out at all Never attempt to carry out maintenance work or repairs on your product yourself Faults and damage should be...

Page 7: ...Number VU 126 6 3 H GB 0010020395 41 694 03 VU 156 6 3 H GB 0010020396 41 694 04 VU 186 6 3 H GB 0010020397 41 694 05 VU 256 6 3 H GB 0010020398 41 694 06 VU 306 6 3 H GB 0010020399 41 694 07 3 Produ...

Page 8: ...d off Sym bol Meaning Explanation Burner anti cyc ling time is active To avoid the need for frequent switching on and off increases the product s working life F XX Fault in the product Fault in the pr...

Page 9: ...the applicable directives as stated on the iden tification plate The declaration of conformity can be viewed at the manufacturer s site 3 7 Benchmark Vaillant is a licensed member of the Benchmark Sch...

Page 10: ...that are available depend on whether a controller is connected to the product You can switch back to the basic display by Pressing to exit the selection levels Not pressing any button for longer than...

Page 11: ...controller Controller oper ating instructions 4 9 Setting the hot water temperature Warning Risk of being scalded by hot water To protect against Legionella the hot water can be heated up to above 60...

Page 12: ...m filling pressures appear in the display 2 Check the filling pressure in the display 1 2 System pressure 0 10 0 20 MPa 1 00 2 00 bar The filling pressure is in the intended pressure range 2 2 Filling...

Page 13: ...r to approx 30 C on both the heating side and the hot water side if available 4 12 2 Draining the heating installation When the unit is switched off for an exten ded period frost protection can be gua...

Page 14: ...ipework and tundish The condensate drain pipework and tun dish must always be penetrable Regularly check the condensate drain pipework and tundish for faults and particularly for blockages You must no...

Page 15: ...mbol these bat teries may contain substances that are hazardous to human health and the envir onment In this case dispose of the batteries at a collection point for batteries 9 Guarantee and customer...

Page 16: ...and Hot water requirement S 22 DHW mode Pump pre run DHW mode Pump pre run S 24 DHW mode Burner on DHW mode Burner on Others S 31 No heat demand Summer mode Summer mode active S 34 Heating mode Frost...

Page 17: ...ion Filling the heating installation section There is air in the heating installation Have your competent person purge the heating installation After three unsuccessful attempts to ignite the flame th...

Page 18: ......

Page 19: ......

Page 20: ...e DE56 1JT Telephone 0330 100 3461 info vaillant co uk www vaillant co uk These instructions or parts thereof are protected by copyright and may be reproduced or distributed only with the manufacturer...

Reviews: