19
Installation manual auroTHERM 0020057143_02
6.2.1
Roof anchor type P (pantile)
A
B
1
2
5 mm
Fig. 6.3 Roof anchor type P
The roof anchor type P can be fixed to the
rafters
(
Pos. A
) or to the
roof batten
(
Pos. B
).
Fixing to rafters
5
3
4
6
1
2
A
B
Fig. 6.4 Fixing to rafters
1. Uncover the rafters where needed. For distances
please see Tab. 6.2 and 6.3.
2. Position the roof anchor.
3. Loosen the upper bolt with the socket/combination
wrench (SW 13) until the height of the roof anchor can
be adjusted.
4. Position the roof anchor at the same height of the
pantiles, so that the upper part of the anchor is on the
roofing, and tighten the bolt with the socket/combina-
tion wrench (SW 13).
5. Screw the roof anchor to the rafters with the 3 sup-
plied bolts.
6. Slide the pantiles back to the original position.
If necessary, adapt the water gutter on the lower (
A
)
or upper side (
B
) of the pantile with a hammer, until
the pantiles are tight.
On-roof mounting 6