30
Installation and maintenance instructions 0020285063_05
G
Technical data
Technical data
–
General
aroSTOR VWL B 200/5 UK
aroSTOR VWL B 270/5 UK
Nominal capacity
197.5 l
269 l
Outer diameter
634 mm
634 mm
Height
1,458 mm
1,783 mm
Weight (when empty)
55 kg
68 kg
Weight (full)
255 kg
338 kg
Material of the product container
Stainless steel
Stainless steel
Heat insulation
Polyurethane foam 50 mm
Polyurethane foam 50 mm
Maximum pressure in the drinking water circuit
0.6 MPa
(6.0 bar)
0.6 MPa
(6.0 bar)
Maximum inlet pressure
0.6 MPa
(6.0 bar)
0.6 MPa
(6.0 bar)
Pressure reducer pressure setting
0.3 MPa
(3.0 bar)
0.3 MPa
(3.0 bar)
Expansion valve pressure setting
0.6 MPa
(6.0 bar)
0.6 MPa
(6.0 bar)
Maximum pressure of the temperature and pressure re-
lief valve
0.7 MPa
(7.0 bar)
0.7 MPa
(7.0 bar)
Maximum temperature of the temperature and pressure
relief valve
90
℃
90
℃
Length of the temperature and pressure relief valve
900 mm
1,245 mm
Post-heating time in accordance with EN 12897
06:20
09:28
Permanent heat losses
1.61 kWh/24 hrs
1.77 kWh/24 hrs
Kiwa certification number
1906704/AMD1
1906704/AMD1
Technical data
–
Electrical specifications
aroSTOR VWL B 200/5 UK
aroSTOR VWL B 270/5 UK
Voltage and frequency of the product's power supply
230 V
–
50 Hz
230 V
–
50 Hz
Max amperage of the power supply circuit
8 A
8 A
Length of the electrical cable supplied
1.5 m
1.5 m
IP rating
IPX4
IPX4
Nominal heat output of the electric back-up heater
1,200 W
1,200 W
Heat input of the electric back-up heater
7 W/cm
2
7 W/cm
2
Fuse
8 A
8 A
Technical data
–
Connections
aroSTOR VWL B 200/5 UK
aroSTOR VWL B 270/5 UK
Connections for the domestic hot water circuit
3/4" outside thread, cylindrical
3/4" outside thread, cylindrical
Connecting the temperature and pressure relief valve
F 1/2
″
F 1/2
″
Air connections (inlet and outlet)
160 mm
160 mm
Technical data
–
Specifications for the heat pump
* In accordance with EN 16147:2017
aroSTOR VWL B 200/5 UK
aroSTOR VWL B 270/5 UK
Refrigerant type
R 290
R 290
Refrigerant volume for complete filling
0.15 kg
0.15 kg
Max. overpressure in the heat pump
2.5 MPa
(25.0 bar)
2.5 MPa
(25.0 bar)
Max. low pressure in the heat pump
1.5 MPa
(15.0 bar)
1.5 MPa
(15.0 bar)
Permitted air temperature
−
7 to 45
℃
−
7 to 45
℃
Sound power level LpA (V1/V2)
40/43 dB
40/43 dB