Vaillant aquaPLUS VUI 362-7 Instructions For Use Manual Download Page 6

6

3 Operation

Instructions for use VUI 362-7

6

Fig. 3.4: Checking the water level 

3.3 Domestic hot water operation

Warning!

The boiler should only be used when the heating
system contains water. Use of the boiler without
water may cause damage to the boiler or its
components.

Setting the maximum domestic hot water
temperature control

• Turn the main switch (2, Fig. 3.5) to the "l" position.
• The domestic hot water temperature can be adjusted

using the hot water temperature control (3, Fig. 3.5).

• Turn the control clockwise to increase the

temperature and anti-clockwise to decrease the
temperature.

As a guide for normal circumstances set the knob to the
one o´clock position.

Note!

This control adjusts the maximum domestic hot
water temperature. If adjusting the control
upwards appears to have no effect on the
temperature, then the boiler is already operating
at full output for the selected flow rate.

Warning!

If you live in a hard water area please do not set
the control knob above the mid (12 o'clock)
position to prevent excessive scale formation
(fig. 3.5).

VRC-VC

C

o

0

I

C

o

1

3.2 Initial checks before turning ON

3.2.1 Open the service valves

• Ensure the cold water service valve  is open. This can

be checked by opening a hot water tap and ensuring
water flows.

• Ensure that the service valves in the heating flow and

return (2 and 1) and the gas service valve (3) are open.

Note!

The flow, return and gas service valves are open
when the line marking has the same direction as
the pipe.

• The pressure relief valves (4) are provided for safety

reasons and must not be interfered with.

Note!

A bottom cover is fitted to the appliance. The
service valves can be seen through the cover.

Fig. 3.3: Opening service valves

3.2.2 Check the water contents

• Check the water contents of the system on the

pressure gauge (1).

The needle on the pressure gauge (1) should be within
the green band (between 1 and 1.5 bar). If the needle
displays a value below 0.75 bar when the appliance is
cold, follow the instructions left by your installer to refill
the system. Alternatively, your installer should be called
to refill the system.

I

0

2

3

1

4

834641_12GB_032005.qxd  09.03.2005 16:42 Uhr  Seite 6

Summary of Contents for aquaPLUS VUI 362-7

Page 1: ...VUI 362 7 For the user GB Instructions for use aquaPLUS Gas fired room sealed fan assisted combination boiler with 15L store...

Page 2: ...n the service valves 6 3 2 2 Check the water contents 6 3 3 Domestic hot water operation 6 3 3 1 Warmstart operation 7 3 3 2 Obtaining hot water 7 3 4 Heating operation 8 3 4 1 Setting the maximum rad...

Page 3: ...Both should be recorded in the Benchmark gas boiler commissioning checklist You can check your installer by calling CORGI direct on 01256 372300 01256 372300 1 4 EC designation The purpose of EC desi...

Page 4: ...or suspect a gas leak Turn off the boiler Do not switch the light or any electrical switches in the hazardous area on or off do not use the telephone in the hazardous area avoid sparking such as ligh...

Page 5: ...g 50 C or Displaying of a status error code 8 Correct burner operation normal flame or lock out crossed out flame Fig 3 2 Display indications 0 I C o C o VRC VC 1 2 3 7 6 5 4 8 3 Operation 3 1 Overwie...

Page 6: ...et the control knob above the mid 12 o clock position to prevent excessive scale formation fig 3 5 VRC VC C o 0 I C o 1 3 2 Initial checks before turning ON 3 2 1 Open the service valves Ensure the co...

Page 7: ...play Reset the hot water temperature control knob to the desired setting Note Irrespective of whether the warmstart facility is switched on or off the boiler will automatically operate to provide hot...

Page 8: ...nd fan will continue to operate for a short period to fully disperse the heat from the boiler Note The boiler incorporates an anti cycling economiser control to prevent energy wasteful ON and OFF oper...

Page 9: ...inguished during operation A new attempt to ignite the flame can then only be performed after pressing the Reset button Press the Reset button 2 and hold for approx 1 second Warning If the boiler stil...

Page 10: ...e VRC VC C o 0 I C o C o C o C o 1 Fig 3 12 Reset 3 6 1 Faults in the hot water system To protect the storage vessel feed pump the appliance is equipped with dry running protection This prevents opera...

Page 11: ...VC C o 0 I C o C o C o I 0 2 If the boiler is not operated for several hours during very cold weather there is therefore the possibility of the system freezing Please ensure that if you are absent dur...

Page 12: ...834641_12GB 03 2005 Subject to alteration...

Reviews: