Instructions for use turboMAX pro
3
Safety; Factory guarantee; Operation
- Do not smoke in the hazardous area
- Turn off the gas supply at the gas meter
- Ventilate the room
- Consult your gas supplier, service agent or other
competent person.
Modifications in and around the boiler
No modifications may be made to the following items:
- The boiler
- The gas, water and electrical supply
- The flue system
- The safety valve for the heating water
- Any structural changes around the appliance that
could affect the operational safety of the boiler.
Explosive and flammable materials
Do not use or store any explosive or highly flammable
materials (e.g. gasoline, paper or paint) near to the
appliance.
Inspection
The boiler should be serviced annually. We recommend
that you sign a service agreement with your service
agent or Vaillant Ltd.
Factory guarantee
Your guarantee
Vaillant undertakes to rectify any manufacturing defect
that occurs within twelve months of the installation
date.
Registering with us
Registration is simple. Just complete the Guarantee
Registration Card and return to Vaillant within 30 days
of installation. Your details will then be automatically
registered within the Vaillant scheme.
Note: No receipt will be issued.
Immediate help
If your Vaillant boiler develops a fault your first action
should be to contact your installer, as his professional
assessment is needed under the terms of our Guarantee.
If you are unable to contact your installer, phone Vaillant
Service Solutions: 0870 6060 777.
Attention!
The device may only be used
• for initial operation
• for testing
• for continuous operation
with the chamber cover closed and with the flue
system fully mounted and sealed.
Operation
Overview
Fig. B.1: Operating elements
Operating controls
1 Maximum radiator temperature control
2 „Reset“ button
3 Indicator lights to display the current operating mode
4 Main ON/OFF control
5 Pressure gauge displaying the pressure in the heating
system
6 Built in control/timer module (if fitted)
7 Maximum hot water temperature control
Indicator lights
Fig. B.2: LED displays
The lights indicate the following operating states under
normal conditions:
1 On: The main ON/OFF switch is set to the ON position
2 On: A hot water tap is opened and there is a demand
for hot water
3 On: There is a demand for central heating
4 On: Fan and flue system are functioning correctly
5 On: Gas valve opened, the boiler is trying to ignite
Flashing: Lack of water in the system
6 On: Burner has lit to provide either central heating or
hot water
7 On: Boiler has tried and failed to light
I
0
1
2
3
4
5
6
7
I
0
5
4
3
7
2
1
VRC-VC
6
833689_22GB_032005 09.03.2005 17:13 Uhr Seite 3