![Vaillant 0010019230 Installation And Maintenance Instructions Manual Download Page 12](http://html1.mh-extra.com/html/vaillant/0010019230/0010019230_installation-and-maintenance-instructions-manual_848585012.webp)
5 Installation
12
Installation and maintenance instructions uniSTOR HP 0020221303_02
5.3.3
Thermostats
70
60 50
40
70
60 50
40
1
3
2
4
1
3
2
4
1
2
3
4
1
Thermal cut-out and re-
set knob for the immer-
sion heater
2
Thermal cut-out and re-
set knob for the primary
circuit
3
Setting the temperature
of the primary circuit
4
Immersion heater tem-
perature control
5.3.4
Cable route
Validity:
Except for VIH RW GB 150 BES
▶
Use the grommets that are included in the scope of
delivery for the cylinder in the electronics box.
Validity:
VIH RW GB 150 BES
▶
Use the grommets that are included in the scope of
delivery for the cylinder in the electronics box.
5.3.5
Connecting the immersion heater to the
power supply
70
60 50
40
70
60 50
40
1
3
2
4
1
3
2
4
L
N
1
L N
3
2
4
1
2
2
1.
Remove the cover for the electrics on the cylinder.
Summary of Contents for 0010019230