Cleaning
After having been de-energized, the conductor system can be cleaned with a standard industrial vacuum
cleaner to remove loose dust or graphite deposits.
CAUTION!
For maintenance and cleaning work where graphite
contact dust may get into the
ambient air, breathing
protection must be used:
►
Breathing protection mask acc. to EN 149, min.
protection level FFP3.
Vahle product ID: 10017880
►
Never blow out the mask with compressed air.
►
Use vacuum with class M filter.
►
Do not eat, drink or smoke during work.
Dust in the vacuum cleaner bag or the air filter can be disposed of as commercial waste in the usual quantities
(up to about 2 liters). Larger quantities must be disposed of in a controlled manner according to applicable law.
Cleaning the conductor system
Requirements:
System free of voltage
Required tools:
⚒
Standard industrial cleaner (e.g. Kärcher, Nilfisk)
⚒
Cleaning brush with nylon bristles (e.g. Kärcher no. 2.863-146.0)
⚒
Screwdriver set
Summary of Contents for VKS10