Manual :
DT-1 Plus (V 0.3)
► The device is capable of imaging the room temperature calibration <CAL>, Differential regulation
cadence <dt>, setting upper and lower limits imaging and control <Lo> <Hi> by the user.
! CAUTION: The last two functions refer to devices for example placed in public places, ho-
tels, schools, etc.
Finally, there is state regulation for all functions of the thermostat after drop or
power failure. To set the specific parameters consult (TABLE 1).
(TABLE 1) ! ATTENTION: The configuration process specific parameters should only be
done by qualified personnel.
► In state <OFF> press continuously and simultaneously for three (3) seconds buttons with sym-
bols . Same with the buttons used to navigate the menu and change the price.
► The button with the symbol in the process of setting specific parameters works like
< ENTRY > or <ENTER>.
► Select the parameter with the arrow keys, press , change the value again with the arrow
keys and then press .
► To exit and save the parameter select End and press .
Messages menu option
CAL
± 3.0 ⁰ C (factory setting 0 ⁰ C).
Calibration accuracy of the reported temperature.
dt
0.1 ⁰ C ..... 3.0 ⁰ C Factory setting 0.3 ⁰ C
Differential: negative change of temperature set point.
Lo
05.0 ⁰ C ..... Hi (Factory setting 5.0 ⁰ C). Setting lower limit value displayed temperature
and control.
Hi
Lo ..... 95.0 ⁰ C (Factory setting 95.0 ⁰ C). Setting price limits on the reported tempera-
ture & control.
Por
Select Off for state auditor after shutoff device.
Select On for state auditor after shutoff device.
(Factory setting Off).
Features & Specifications
Location Imaging & controller
settings
+05,0 ⁰ C to +35,0 ⁰ C in steps of 0,1 ⁰ C
Differential Controller
Adjustable -0,1 ⁰ C to –1,0 ⁰ C in steps of 0,1 ⁰ C.
Setting Precision
thermometer
Adjustable -3,0 ⁰ C to +3,0 ⁰ C in steps 0,1 ⁰ C.
Dimensions
110 Χ 62 Χ 31mm
Power supply
~230V AC/50Hz ±10%
Relay Contact Resistance
6Α/250VAC
Operating Temperature
-10,0⁰C to +50,0⁰C
General Function:
With the completion of the installation of the thermostat device works like a
thermometer space. Pressing the <button ON / OFF> (Figure 3) the device turn on or off the green
ON indicator lit or off respectively. The setting temperature is only in state <ACTIVE> <ON> with but-
tons (Figure 3). When setting the desired temperature, the green indicator marked <ON/SET>
lights & extinguished successively (Figure 3).When setting the desired temperature is greater than dt
(factory -0,3 C ⁰), the temperature is shown on our site, then the device activates the heater relay
means available. In this case the red indicator lights up with the symbol (Figure 3). The button
with the symbol only works when the device is in standby <ON> and provides us with the option
set two different temperatures, or DAILY NIGHT. When selected, the NIGHT mode the yellow indica-
tor lights (Figure 3).
MANUAL DT-1 Plus V 0.3 en-eg
VAGEO HVAC products designed and manufactured in Greece by INTELCO Electronics
with exclusive distributor PTS.
St. Anthimos Gazi 7 -121 32 Peristeri Attica T. + 30 210 5747683 F. + 30 215 5550595
Email: [email protected], [email protected] web: www.pt-s.gr