![VAF instruments 258 Technical Manual Download Page 6](http://html2.mh-extra.com/html/vaf-instruments/258/258_technical-manual_3143989006.webp)
5
If the Anderol lubricant is not available, a substitute with equivalent properties may be used. To assist
fieldmen in obtaining suitable lubricants for the meter-register and ticket printers, the following list
showing equivalent lubricants has been prepared:
OIL:
AEROSHELL FLUID NO.
3
ARGEOYLE ARTIC OIL LIGHT
REGENT SPINTEX OIL 60
CASTROL HYSPIN - 40
GREASE:
AEROSHELL 14
ESSO BEACON - 325
3.6.2 POINTS TO LUBRICATE
OIL
All points indicated as (oil) on figure l should be lubricated with oil as described above. This includes
all shaftst studs, and bosses on which a moving part bears.
GREASE
Grease should be applied to all points indicated as (grease) on figure 1.
NOTE:
The oil and grease should be applied with a srnall brush to make certain that all areas will be properly
lubricated. In this manner, the amount of lubricant being used will be controlled easier.
3.7 ASSEMBLY AFTER LUBRICATION
1. Install the gear plate on the bottom of the housing and secure with screws.
2. Install the meter-register in the housing and secure with three button-head bolts.
3. Install the cover (if present) and lever and secure with bolts.
3.8 METER REGISTER INSTALLATION
Mount the meter-register on the meter and secure the two with bolts removed in paragraph 3.2.