Installation
4
5
Operation - ceramic disk version
Cover
Control
handle
Spout
Cover
Control
handle
Cold inlet
Before installing your new mixer, flush through the pipework to ensure removal of
debris, turn off the water supply.
Note:
The valve must be connected to rigid pipe work for support as there are no back
nuts or fixing holes.
Mark a horizontal line on the wall at the required height, mark the position of the taps
and the divertor with centres of 100mm, drill 3 x 30mm holes.
Slide the valve assembly through the holes from the back.
Screw the spout cover onto the spout and then into the centre hole of the valve.
Screw the valve covers over the valves and up to the wall surface, screw on the inner
cover, slide the handle onto the splines and secure with the screw. Screw on the cover.
Connect the water supply to the inlet pipes. The hot water should be connected to the
left hand inlet.
Hot inlet
Screw and
cover
Hot tap
- moving the
tap handle clockwise will
increase the flow of water.
Cold tap
- moving the
tap handle anti-clockwise
will increase the flow of
water.
Screw and
cover
Valve
Inner
cover
Inner
cover
Spout
cover