Installation
4
5
Installation
Valve
Wall plug
Showerhead
Mounting
boss
Handset
holder
Screw
Grub screw
Before installing your new mixer, flush through the pipework to ensure removal of
debris, turn off the water supply.
Prepare the wall with 2 flush ½” connectors at 150mm centres. Connect the water
supply to the inlet pipes. The hot water should be connected to the left hand pipe.
Screw on the 2 offset connectors followed by the covers.
Screw the locking nuts on the valve onto the connectors, some adjustment can be
made to the offset connectors to align the centres and level up the valve.
Note:
If you are installing this item using our fixing brackets (product code:
WG-0SHR-C/P) please ensure a ¾ fibre washer is used in addition to the
mesh filter washers in the valve inlets in order to create a watertight seal.
Also due to the location of the NRVs (Non Return Valves) in the offset connector, when
using the WG-049 Bracket and Shroud an additional NRV must be fitted in line to each
of the hot and cold supplies.
Control
handle
Temperature
override button
Riser connection
Locking nuts
Cover
Offset connector
Cover
Temperature
control
Top riser
Support
bracket
Locking
nut and seal
Riser
Washers
Handset
Hose
Hose connection
Riser
Hexagonal key
Warning!
Please check for any
hidden cables and pipes before drilling
holes in the wall.
Screw together the riser and top riser.
Remove the locking nut and seal from
the valve, slide the locking nut onto the
riser followed by the seal (tapered end
last) push the riser into the valve, slide
down the seal and nut and tighten to
the valve, but do not tighten.
Using a level make sure the riser is
vertical and mark the position of the
support bracket onto the wall, remove
the riser.
In the centre drill a 6mm hole 30mm
deep for the wall plug and secure the
mounting boss to the wall with the
supplied screw (see inset left above).
Position the riser back onto the valve
and push the support bracket over
the boss, tighten the support bracket
in position with the grub screw and
tighten using the hexagonal key.
Tighten the nut on the valve to secure it
to the riser.
Finally place a rubber washer into the
showerhead and screw onto the top
riser. The angle of the showerhead can
be adjusted as required.
Hose connection
Place one of the rubber washers into the
cone end of the hose and screw to the
handset.
Place the second rubber washer into the
other end of the hose and attach it to
the valve.
Valve