background image

Mono Basin Mixers

OMIKA

Keep for future reference

Installation Guide

100M
100
100E

it’s a personal experience

Vado

Wedmore Road, Cheddar, Somerset, England BS27 3EB

tel 01934 744466.      fax 01934 744345

aftersales

@

vado.com

www.vado.com

This instruction booklet covers these models:

OMI-100M, OMI-100, OMI-100E.

Version 1, 1-8-17

Summary of Contents for OMIKA 100

Page 1: ...ation Guide 100M 100 100E it s a personal experience Vado Wedmore Road Cheddar Somerset England BS27 3EB tel 01934 744466 fax 01934 744345 aftersales vado com www vado com This instruction booklet covers these models OMI 100M OMI 100 OMI 100E Version 1 1 8 17 ...

Page 2: ... pipe connections all supply pipes MUST be thoroughly flushed to remove debris Failure to do so could result in damage or low flow from the mixer unit Water Supply Water Fittings Regulations 1999 Schedule 2 Section 13 The fitting of isolating valves to the inlet feeds is advised for ease of maintenance Please take great care when installing this mixer not to damage its surface Please note if insta...

Page 3: ...base of the mixer body Position the mixer on the basin Note If you have thin basins of 7mm or less use the spacer provided Spacer Basin 7mm If you are using the spacer push the hoses up through the basin hole Screw the two flexible hoses into the hot and cold connections on the mixer body and hand tighten only do not over tighten The red hose hot should be connected to the left hole and the blue h...

Page 4: ...dimensions 100m Valve dimensions 100e 108mm 121mm 50mm 50mm 78mm 78mm 48mm 48mm 25mm 25mm 17mm 17mm 39mm 39mm 33mm 33mm 19mm 19mm 105mm 128mm 7mm 7mm 4mm 4mm 13mm 13mm 126mm 50mm 78mm 48mm 25mm 17mm 161mm 33mm 19mm 250mm 7mm 4mm 13mm ...

Page 5: ...on Process This can be done via the VADO website or via phone to our aftersales team Registration must be completed within 6 months from date of purchase Under the extended guarantee period VADO will at its option offer to supply any replacement product or component part assessed to be defective SEE NOTE 3 The guarantee whether standard or extended is non transferable to any subsequent owner All c...

Page 6: ...ss the world therefore you can expect exceptional product quality and outstanding customer service This product has passed through stringent quality assurance processes coupled with demanding lifecycle mechanical testing to ensure it reaches the exacting standards that allow us to offer our premium 12 year guarantee We work to ensure our product designs are harmonious with all sanitaryware so when...

Page 7: ...to ensure the appearance is retained We recommend cleaning all products with a soft damp cloth ONLY and advise strongly against the use of all aggressive corrosive cleaning products i e powders and liquids If these instructions are not followed this may invalidate your guarantee in the event of a problem occurring Notes ...

Page 8: ...1 pair 4 Aerator housing OMI AERATOR C P 1 5 Fixing kit OMI FIXING KIT 1 6 Flexible hose T x M10 400mm FLX 1pair 7 Flow regulation Uncoded N A 8 Installation guide User manual 1 Mono Basin Mixers OMIKA Keep for future reference Installation Guide 100M 100 100E WHERE INSPIRATION FLOWS OMIKA Mono Basin Mixer User Guide Keep for future reference ...

Reviews: