VADO celsius Installation & Maintenance Instructions Download Page 3

  

6

  Dimensions

  

3

  

Operating Specifications

  Operation

Hot Water Supply Temperature:
Maximum: 85° C
Minimum: 10° C higher than the maximum required mixed temperature (advise 65° C)

Operating Pressure
Minimum operating pressure 0.2 bar
Maximum operating pressure 5 bar

100mm

46mm

66mm

267mm

1/2”

Moving the handle 
controls the flow of 
water.

Moving the handle will 
increase/decrease the 
water temperature. 

Pushing down on 
this button will 
override the set 
temperature.

150mm +/–20mm

  Maintenance

IMPORTANT:  

Please see the below procedure for isolating the thermostatic valve.

1. Isolate the incoming hot and cold water to the valve.
2. Turn shower valve on to check isolation, please ensure that your body/hands are not 
under the flow of water as there is a potential for delivery of hot  water.
3. Remove temperature control handle (refer to instruction leaflet) and temperature 
stop ring (essential).
4. With shower in the on position, replace temperature handle on thermostatic valve 
(ensure temperature stop ring has been removed).
5. Turn temp handle fully anti clockwise until stop point is reached and can be turned 
no further , please ensure that your body/hands are not under the flow of water as 
there is potential for delivery of hot water if isolation has been unsuccessful.
6. Turn temperature handle fully clockwise until you feel a click.  
7. If there is no flow of water coming from the outlet during both points 5 and 6 
isolation has been successful, you may now remove and maintain the cartridge.
8. If at any of the above point’s water continues to flow please isolate at an alternative 
point within the system for both hot and cold and repeat points 2-8.

Summary of Contents for celsius

Page 1: ...d returns by registered means is therefore recommended Under this guarantee which is non transferable Vado will at its option repair or replace free of charge any product or replacement part found to be defective The guarantee does not extend to any consequential loss or damage After repair or replacement the relevant guarantee period will be calculated from the original date of purchase The relev...

Page 2: ...icing and maintenance No costs relating to inadequate access can be accepted Care of the mixer Our products are finished to the highest standard and due care needs to be taken to ensure their looks are retained We recommend cleaning all products with a soft damp cloth ONLY and advise strongly against the use of ALL cleaning products i e powders and liquids If the above instructions are not followe...

Page 3: ...water as there is a potential for delivery of hot water 3 Remove temperature control handle refer to instruction leaflet and temperature stop ring essential 4 With shower in the on position replace temperature handle on thermostatic valve ensure temperature stop ring has been removed 5 Turn temp handle fully anti clockwise until stop point is reached and can be turned no further please ensure that...

Page 4: ...stop on the stop ring is at 12 o clock and replace the handle with the temperature override button also pointing at 12 o clock being careful not to turn the spline of the valve The valve setting is now calibrated to suit your requirements Secure the handle and replace the lever Before installing your new mixer flush through the pipework to ensure removal of debris turn off the water supply Prepare...

Reviews: