16
OPERATING FUNCTIONS
Power on indicator
(fig.25)
When the electricity supply to the shower is
switched on at the isolating switch, the power
‘
ON
’ indicator will light.
Low water pressure cut-out
If the water pressure falls below the minimum
required for correct operation of the unit, power
will be switched off to the heating elements
preventing any maintained temperature rises
(water will continue to flow).
Power will automatically be restored when
adequate water pressure returns.
TP – Temperature Protection
During normal operation if the temperature
exceeds the showering safety limit the power
to the elements will be removed completely,
although water will continue to flow. When the
temperature has cooled sufficiently, power to the
elements will be automatically restored to the
settings at the time of interruption.
Safety cut-out
The unit is fitted with a non-resettable
thermal cut-out safety device. In the event of
abnormal operation which could cause unsafe
temperatures within the unit, the device will
disconnect the heating elements. It will require a
visit from a qualified engineer to determine the
nature of the fault and replace the safety device,
once the unit has been repaired.
NOTE:
In normal use, it is in order to leave the
water supply permanently on to the shower
unit, but as with most electrical appliances,
the
unit
MUST
be switched off at the isolating
switch when not in use.
10
Continued
SECTION
Fig.25
Power
‘ON’
indicator