8
9
Installation
Remove the backing paper from the seal located on the back of the plate. Slide
the plate over the valve, push onto the wall until it makes contact.
Carefully slide the control handle onto the valve and secure in position with the
grub screw located within the handle using the hexagonal key supplied, replace
the screw cover.
Screw on the diverter handle.
Note:
If the valve is sited within in a wet environment, it is recommended that
once the valve is commissioned the plate is sealed with a thin bead of sealant
around three sides to provide a water-tight seal between the plate and the wall
material, leaving the bottom edge free to allow for maintenance purposes.
Operation
Pulling the mixer lever outwards will
increase the flow of water.
Moving the mixer lever from right to left
will increase the water temperature.
Moving the mixer lever from left to right
will decrease the water temperature.
Pull the diverter handle and turn
clockwise to lock into position.
Turn clockwise again to release the
diverter and go back to the primary outlet.
On
Cold
Hot
Valve
Backing paper
Plate
Screw cover
Handle
Diverter
handle
Grub screw