COMPLETING THE INSTALLATION:
Connect the Vaddio 36 VDC power supply to an AC outlet. Power will travel down the Power Cat. 5 cable to
the EZIM, powering the camera. The camera will “Home” to a centered position ready for control information
from the provided IR Remote Control or RS-232 Camera controller of the integrators’ choice. To insure
proper continuity of control and operation of the cameras, the RS-232 controller (control system or joystick)
should be powered on after the camera.
Step 10: Setting the IR Pass-Through Adjustment (optional)
The PRO system is capable of transmitting IR signal frequencies between 25 to 45 kHz. Connect the IR
output from the Quick-Connect PRO to either the IR input on a third party device or a Xantech™ IR probe
(compatible models: 282MRP or 283M). See Figure 8 for terminating the Xantech probe. NOTE: Vaddio has
tested compatibility of the IR forwarding with Sony, Vaddio, Polycom and TANDBERG remote controls.
IMPORTANT NOTE: The IR Gain adjustment is factory set for distances below 300 feet
(91.4 meters), and should not have to be adjusted unless the Cat. 5 cabling distance is
over this length. For cable runs above 300 feet, slowly adjust the gain level up while
pressing functions on the remote control, pointed at the HD1 camera using the WallVIEW
PRO system. Once all remote control functions are operating from the remote, through the
camera’s IR sensor, the IR gain is adjusted properly.
CARE AND CLEANING
•
Do not attempt to take the products in the system apart. There are no user-serviceable components.
•
Keep the devices away from food and liquid, and do not spill liquids on the products
•
For smears or smudges on the lens, wipe with a clean, soft cloth. Do not use any abrasive chemicals on
the camera body at any time.
OPERATING AND STORAGE CONDITIONS
Do not store or operate the WallVIEW PRO System under the following conditions:
•
Temperatures above 40°C (104°F) or below 0°C (32°F), for Indoor Use Only
•
High humidity, condensing or wet environments
•
Dusty
environments
•
In inclement weather
•
Under severe vibration