Configuring the Switcher for Your Network
N
ETWORKING PAGE
Note
DHCP is the default setting, but the switcher will use the default address of 169.254.1.1 if no DHCP server
is available.
You will be able to enter the IP address, subnet mask, and gateway only if you set IP Address to Static.
Note
If you don't completely understand all the implications of the steps below, please contact your IT staff or
Vaddio Technical Support for assistance. Changes in network configuration can result in loss of network
contact with the device.
1. Edit the device hostname if necessary. The hostname serves as the device URL. If the network
supports hostname resolution, you can use the hostname instead of the device's IP address when you
open a web interface session. The hostname is also used as the filename for exported configuration
data, so it can help you identify the source of an exported data file.
2. If the switcher needs to use static IP addressing, select Static.
3. For static IP addressing, enter the appropriate IP address, subnet mask, and gateway address.
13
Integrator's Complete Guide to the AV Bridge MatrixMIX Multipurpose AV Switcher