ADJUSTING CUT-IN PRESSURE

For a smooth, more reliable changeover 
between tank and mains water, adjust 
the cut-in pressure from the default 1.5 
Bar to 2.2 Bar. Follow the steps below 
accordingly.

1.  Ensure your pump is primed. Then, turn on 

the power at the power point.

2.  Locate the adjustment screw at the back  

of the VFB-APC.

3.  Using a flat head screwdriver, turn the 

adjustment screw clockwise until you  
reach the correct pressure (approx 3.5  
full 360° turns).

4.  Confirm the pressure has been correctly 

adjusted by slowly opening a tap outlet 
and checking the gauge on the side of the 
VFB-APC. If the gauge reads 2.2, the cut-in 
pressure has been successfully adjusted.

Your pump solution is now ready for operation!