![VADA VFB-J60 Installation Manual Download Page 26](http://html1.mh-extra.com/html/vada/vfb-j60/vfb-j60_installation-manual_3143068026.webp)
20mm isolation
valve
20mm isolation
valve
VFB-MSU20
25mm
barrel union
25mm barrel union
25mm Y-Strainer
Mains pipe
min 20mm
Solid level base
25mm
isolation
valve
25mm
swing
check
valve
100mm
To house
From mains
House wall
VFB-APC
Discharge pipe
min 20mm
Recommended
150mm
Min 100mm
26
VADA FLOW BOSS
JET PUMP
VFB-J60
INSTALLATION MANUAL
INSTALLATION
4. Connect the power lead to the power
outlet. Do not turn on.
a. If installing the Jet Pump by itself,
simply connect the two supplied cords
using the IEC socket and plug.
b. If installing an VFB-APC or VFB-MSU20,
connect the IEC socket from the pump
to the IEC plug cord on the VFB-APC or
VFB-DSU.
Note:
Supply voltage that is outside the
limits specified can cause the motor to
overheat leading to overload tripping, reduced
component life or seriously damage pump,
voiding warranty.
Note:
For additional protection, the pump
must be supplied from an outlet protected by
a residual current device – RCD (also known
as an Electrical Leakage Circuit breaker –
ELCB) with a maximum rated residual current
of 30mA.
Note:
Do not use extension cords. This can
cause the voltage to drop.
OFF