VADA VFB-HM80 Installation Manual Download Page 8

15

14

VADA FLOW BOSS 

HORIZONTAL MULTISTAGE PUMP

 

VFB-HM80 

INSTALLATION MANUAL

PART 2: SUCTION SET UP

Now that your Horizontal Multistage Pump 
is positioned, it’s time to set up the suction 
pipework. This will run from your tank/water 
source to your pump. 

1.  Select pipe that is re-enforced and crush 

resistant (non-collapsible), with an internal 
diameter of 25mm or larger.

2.  Install an isolation valve at the tank/water 

source outlet. 

3.  If the tank is below ground, install a foot 

valve at the point of entry on the suction line.

4.  Connect the suction pipe to your Horizontal 

Multistage Pump. Ensuring both an inline 
filter and barrel union have been installed 
in the suction line. The inline filter prevents 
dirt and debris entering the pump and will 
prolong product lifespan. 

Note: 

The length of the suction pipe should 

only run between 1–2 metres.

Note:

 Install a check valve for optimal 

performance should the tank be above ground 
but lower in elevation than the suction inlet of 
the pump.

5.  Check that all fittings connected to the 

suction pipe are airtight.

INSTALLATION

PART 1: PUMP LOCATION

Let’s get down to business. 

Note: 

Ensure the pump is being installed by a 

qualified, licensed personnel. The pump should 
be in good condition and should be used in a 
residential application.

Note: 

The length and the diameter of the 

discharge pipe impacts the pressure and flow 
rate the VFB-HM80 can deliver.

Note: 

all components used must have a 

pressure rating that exceeds the maximum 
pressure of the pump by an appropriate  
safety factor.

1.  Ensure you have access to a 10A 

weatherproof outdoor powerpoint in a dry 
and flood free location. Do not plug the 
power cable in. 

Note: 

If you do not have access, arrange  

an electrician to install one. 

2.  Find a location for your pump as close to 

your water source as possible. Use either 
a poly, or concrete base slab to mount the 
pump. This location should be stable, dry 
and on a separate footing from your home. 

Note: 

It is recommended the pump should  

be no further than 3 metres from the tank.

In accordance with AS 3350.2.41 
we are obliged to inform you that 
this pump is not to be used  
by children or infirm persons and 
must not be used as a toy by 
children.

The Auto Pressure Control is 
pre-set by the manufacturer 
with a pump start pressure of 
1.5 bar (this can be adjusted). 
The maximum pump pressure 
must be 0.8 bar above the start 
pressure for the pump to reach 
automatic shut-off.

The Pressure Control has a safety 
valve preventing water emission 
in case of diaphragm damage. 
DO NOT REMOVE.

Ensure that the power lead 
remains disconnected until you 
have completed the installation 
process.

100mm

100mm

Suction pipe min 25mm

Foot valve

25mm

25mm Y Strainer

25mm Barrel union

10

0m

m

Isolation

valve

Summary of Contents for VFB-HM80

Page 1: ...HORIZONTAL MULTISTAGE PUMP INSTALLATION MANUAL VFB HM80...

Page 2: ...urchase invoice number Product serial number Product model number THANK YOU A smooth day is a good day That s why Vada is dedicated to creating pump solutions that you can count on With a focus on eas...

Page 3: ...oose between the Auto Pressure Control and the Mechanical Switching Unit or the Digital Water Switching Unit COMPATIBLE VADA PRODUCTS The Vada Flow Boss VFB HM80 is a self priming Horizontal Multistag...

Page 4: ...oss Auto Pressure Control VFB APC gives you perfect control of household pressure pumps guaranteed Designed with an LED light panel to signal the state of operation a built in pressure gauge to allow...

Page 5: ...iew the complete Digital Water Switch Manual for further details on set up operation and even troubleshooting HELPFUL HINT KNOW YOUR PRODUCT VFB MSU25 SPECIFICATIONS VFB MSU25 The Vada Flow Boss Mecha...

Page 6: ...flammable liquids Pumping liquid containing abrasive solids stones ceramics etc What you ll need to supply Suction Pipe internal diameter of 25mm or larger Discharge pipe internal diameter of 25mm or...

Page 7: ...ater Switching Unit VFB DSU Thread tape Teflon tape Float switch kit 25mm barrel union Barrel union kit x2 mesh washer inline filters 25mm or larger male hose barb Access to a 10A outdoor powerpoint H...

Page 8: ...l application Note The length and the diameter of the discharge pipe impacts the pressure and flow rate the VFB HM80 can deliver Note all components used must have a pressure rating that exceeds the m...

Page 9: ...mounted above a tank follow steps outlined in Part 4B PART 4A PRIMING A SURFACE MOUNT PUMP AND TANK 1 Ensure the water level in your tank sits above the tank outlet This will ensure the pump does not...

Page 10: ...no leaks are present proceed Recommended length 150mm 25mm barrel union Y Strainer Suction pipe Min 25mm Solid level base 100mm 50mm 25mm Foot valve non return valve Foot valve minimum of 100mm from b...

Page 11: ...s and house water line Power on Pump on Error Restart AUTO PRESSURE CONTROL FLOW BOSS 240 50Hz Max 1 5kW Max 1MPa 8A IP65 2 Position the Auto Pressure Control VFB APC between the pump and the first ou...

Page 12: ...screw at the back of the VFB APC 3 Using a flat head screwdriver turn the adjustment screw clockwise until you reach the correct pressure roughly this will be 3 5 full 360 turns 4 Confirm the pressur...

Page 13: ...hing unit to the incoming mains water supply This is marked MAINS with an arrow pointing out of the VFB DSU indicating water flow direction Note Brace this fitting to prevent movement while connecting...

Page 14: ...ing an VFB APC or VFB MSU25 connect the IEC socket from the pump to the IEC plug cord on the VFB APC or VFB DSU Note Supply voltage that is outside the limits specified can cause the motor to overheat...

Page 15: ...SU however these steps apply to all possible set ups Ensure that the pump has been successfully primed 1 Open the gate valve on the suction line 2 Slowly open the gate valve on the discharge line to 5...

Page 16: ...n off power to motor and remove plug from power outlet before working on pump or motor 5 Open the outlet on discharge line and open isolation valve on the discharge line to 100 This will assist with r...

Page 17: ...litres per minute For example in the pump performance curve below you can see that if the Horizontal Multistage Pump VFB HM80 has a discharge head between 28 37 metres then the pump will produce 34 5...

Page 18: ...ssure 800kPa 8 bar MOTOR IP rating IP55 motor Speed of rotation 2850rpm motor Insulation Class F motor Enclosed externally ventilated Capacitor permanently activated Thermal protection built into the...

Page 19: ...maximum allowable pressure in buildings is 500 KPa TECHNICAL INFORMATION VFB MSU25 37 36 VADA FLOW BOSS HORIZONTAL MULTISTAGE PUMP VFB HM80 INSTALLATION MANUAL C F H I A B J G D E A 52mm B 181mm C 80...

Page 20: ...Ensure that the power is turned on and check the connection to the power point 2 Fuse may have blown 3 Electrical power line may have been damaged The pump motor protection may have tripped Ensure the...

Page 21: ...nce in the pump fan 1 Disconnect all electrical power 2 Remove the fan cover 3 Rotate the fan by hand and it should rotate freely There may be cavitation in the pump demand for water is higher than it...

Page 22: ...o long or the internal diameter may be too small 1 Reduce either the suction height or distance 2 Increase the suction pipe internal diameter to same size as the pump inlet or larger The pump does not...

Page 23: ...B APC 2 Inspect internals 3 Clean or free debris 4 Ensure that an in line strainer filter is fitted in the suction line between the pump and the tank A pressure controller or mains switch over device...

Page 24: ...ease the suction pipe internal diameter to same size as the pump inlet or larger The pump may have been incorrectly sized for the application Contact the Reece store where the product was purchased fr...

Page 25: ...may be above the check valve on the discharge line The weight of water can force the check valve on the discharge line to close This prevents air being expelled from casing and suction line affecting...

Page 26: ...first impeller not allowing pressure to be created 1 Disassemble pipework and pump housing 2 Clean impellers It is recommended to call a pump technician or licensed professional The Digital Water Swi...

Page 27: ...tank Ensure foot valve is installed fill up suction line and casing from discharge point 3 Activate all appliances outlets sequentially from the nearest to the furthest outlet Repeat if necessary 4 If...

Page 28: ...ives or an authorised customer service workshop and any attempt to repair the device by the customer or unauthorised third parties shall terminate the warranty WARRANTY CONDITIONS The warranty will ap...

Page 29: ......

Reviews: