  The residual 

leak rate of the equipment

 might render possible an exchange of 

gas, albeit extremely slight, between the environment and the vacuum system.

  Adopt suitable measures to prevent contamination of the pumped substances or 

the environment.

•  Ensure that no parts of your clothing, hair or fingers  can be caught or drawn in at 

the inlet of the pump. Never insert fingers or drop any other object into the inlet or 

outlet. 

•  Pumping at high inlet pressure may lead to overpressure at the gas ballast valve. 

Pumped gases or condensate might be expelled if the valve is open. If an inert 

gas supply is connected to the gas ballast, ensure that its inlet pipeline is not 

contaminated.

 •  Pay attention to the safety symbol ”hot surfaces” on the equipment. Hot parts 

may cause burns if touched. Adopt suitable measures to prevent any danger 

arising from hot surfaces or electric sparks. During normal operation the diffusion 

pump becomes very hot, especially the vacuum connection. Do not touch, risk of 

burning! Avoid contacting or covering the pump with burnable material, or mate-

rial which may be damaged due to high temperature, e.g., electrical power cord.

  Ensure that hot surfaces of the pump do not cause burns. Provide a suitable 

contact guard if necessary.

Attention

: If the maximum permissible inlet pressure or the backing pressure at 

the diffusion pump are exceeded, pump fluid might enter other parts of the vacuum 

system.

Provide appropriate protective measures to allow for the possibility of failure and 

malfunction. The protective measures must also allow for the requirements of the 

respective application.

In case of overload, the motor of the rotary vane pump is shut down by a 

self-hold 

thermal cutout

 in the winding. 

Note

: Only manual reset is possible. Switch off the pump and disconnect from the 

power source. Identify and eliminate the cause of failure. Allow the pump to cool 

down sufficiently before restart. 

In case of excess temperature the motor of the diffusion pump is shut down by a 

safety switch

.

•  

Attention

: After cooling down, the heating of the diffusion pump restarts auto-

matically. Adopt suitable measures if a restart is a potential source of danger.

Maintenance and repair

 

In order to comply with laws (occupational, health and safety regulations, safety at 

work law and regulations for environmental protection) vacuum pumps, components 

and measuring instruments can only be returned when certain procedures (see sec-

tion ”

Repair - Maintenance - Return - Calibration

”) are followed.

  Ensure that the pump cannot be operated accidentally. Never operate the pump 

if covers or other parts of the pump are disassembled. 

  Switch off the pump. Disconnect the electrical power cord and wait two minutes 

before starting maintenance to allow the capacitors to discharge. 

 

Note

: The pump may be contaminated with process chemicals, which have been 

pumped during operation. Ensure that the pump is completely decontaminated 

NOTICE

Summary of Contents for HP 40B2

Page 1: ...completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999069 28 04 2016 Technology for Vacuum Systems...

Page 2: ...sted intensively including an endurance run of 24 hours Any faults even those which occur rarely are identified and can be eliminated immediately After completion of the endurance run every pumping un...

Page 3: ...and operation 14 Setting up and installing 14 Getting started 14 During operation 15 Shutdown 16 Accessories 16 Troubleshooting 16 Maintenance 16 Repair Maintenance Return Calibration 17 EC Declaratio...

Page 4: ...immediately Store the equipment in dry and non corrosive conditions Intended use Do not use the pump or any system parts on humans or animals Ensure that the individual components are only connected c...

Page 5: ...Do not operate the pump with overpressure at the inlet Avoid overpressure of more than 1 2 bar absolute in the event that inert gas is connected to the pump to the gas ballast or to a venting valve N...

Page 6: ...ons and guidelines Implement the required actions and adopt suitable safety mea sures Ambient conditions Adopt suitable measures in case of differences from recommended conditions e g using the equipm...

Page 7: ...bstances from the pump outlet install an appropriate collecting and disposal system and take protective action for pump and environment You must take suitable precautions to prevent any formation of e...

Page 8: ...ssary Attention If the maximum permissible inlet pressure or the backing pressure at the diffusion pump are exceeded pump fluid might enter other parts of the vacuum system Provide appropriate protect...

Page 9: ...Use appropriate protective clothing safe ty goggles and protective gloves Wear parts have to be replaced regularly Never operate a defective or damaged pump Vent the pumping unit before starting maint...

Page 10: ...ump Pump fluid capacity of diffusion pump ml 30 Maximum pumping speed l s 22 37 Ultimate vacuum mbar 1 x 10 6 Maximum permissible inlet outlet pressure absolute bar 1 1 Maximum pressure difference bet...

Page 11: ...ffusion pump AX 65 2 Backing pump RZ 2 5 3 Backing pump RZ 6 4 ON OFF switch diffusion pump 5 ON OFF switch backing pump 6 Rating plate of pumping unit 7 Connection diagram 8 Handle Position Component...

Page 12: ...idity of this document with respect to his product Manual no 999069 28 04 2016 An oil mist filter for installation at the outlet of the rotary vane pump RZ 6 is separately packed Pay attention to the...

Page 13: ...be used and distributed completely and unchanged It is strictly the users responsibility to check carefully the validity of this document with respect to his product Manual no 999069 28 04 2016 HP 63B...

Page 14: ...matic ventilation system Use connecting hoses with large diameter and keep them as short as possible to avoid flow losses Locate the pump as closely as possible to the application Always install outle...

Page 15: ...V2 once the pressure inside the vacuum vessel is below 0 1 mbar Open fore vacuum valve V1 Open high vacuum valve V3 Note If the fore vacuum M1 rises above 0 1 mbar close the high vacuum valve V3 and p...

Page 16: ...e diffusion pump Proceeding in accordance with the instructions given above ensures that the diffu sion pump is kept under vacuum no condensate build up in the pump fluid To avoid possible formation o...

Page 17: ...t are no original components Drain the device completely of fluids and residues Decontaminate the device Close all openings airtight especially if using substances hazardous to health To expedite repa...

Page 18: ...ed for service staff 11 If the paint is damaged we wish a repaint or a replacement of parts for reason of appearance repaint and replacement at customer s expense yes no 12 Legally binding declaration...

Page 19: ...de pompage Typ Type Type HP 40B2 HP 63B2 Artikelnummer Order number Num ro d article 699029 2612089 699037 Seriennummer Serial number Num ro de s rie Siehe Typenschild See rating plate Voir plaque si...

Page 20: ...lts obtained under test conditions for specific applications depend on a number of factors beyond our control It is therefore strictly the users responsibility to very carefully check the validity of...

Reviews: