10
11
...INSTALLATION...
Installation of vacuum hose and air filter to vacuum pump
The air filter should be installed in a position where it is easily accessible and clearly
marked to indicate the lifting unit to which it is connected. Start by hanging up the
vacuum hose in the suspension system from which the lifting unit is hung (such as
from a traversing crane system).
Connect the vacuum hose to the lifting unit top swivel and to the air filter.
Also connect the vacuum hose between the air filter and the vacuum pump.
NOTE! The arrow on the air filter should point in the direction of the hose which
goes to the vacuum pump.
Make sure that there is no risk that the vacuum hose could be pinched anywhere
along its length, or come into contact with objects which might damage it.
!
!
!
A qualified electrician must carry out the electrical installation. A wiring diagram is
included in the vacuum pump junction box.
The electrician must check that air is blown out through A (please refer to the
illustration below), to ensure that the vacuum pump motor rotates in the correct
direction. NOTE! Never operate the pump without the filter attached.
The electric cable should be run through the cable transition provided (please refer
to the illustration below).
If several Vaculex TP units are to be installed, the vacuum pumps must be marked to
make it clear which Vaculex TP each pump is connected to.
Electrical installation of the electrical vacuum pump.
!
!
!
!
A
B
Cable transition