works within 2048 spots (one over exposed pixel counts as
one spot). Static defect patching will fail if the spots count
exceed this number, please follow methods below to setup
static defect spot patching.
(1)
Main Menu \ LENS IRIS Set to CLOSE, this is to avoid light
passing through ISP module.
(2)
Main Menu \ ISP SETTING \ EXPOSURE \ DEFOG set to OFF。
(3)
Main Menu \ ISP SETTING \ EXPOSURE \ AGC set to 1。
(4)
Main Menu \ ISP SETTING \ SPECIAL \ DEFECT \ LIVE DPC set
to OFF。
(5)
Main Menu \ ISP SETTING \ SPECIAL \ DEFECT \ STATIC DPC
set to ON。
Press ENTER to access STATIC DPC settings as below.
(6)
Adjust SENS-UP (SLOW SHUTTER) level, this means when
SLOW SHUTTER is enabled, the number of defect spot
present.
(7)
Adjust AGC level, means the number of defect spot present
when AGC started.
(8)
Adjust LEVEL, means the defect spot threshold. When defect
spot is brighter then this level, the system will start patching
procedure.
(9)
Next move to START, then press ENTER, the “Close IRIS”
notification will appear. Then press ENTER to start defect spot
patching procedure.