Dip Settings
Installation
External Wiring
Login IP camera
Safety Precautions
This sector is for protocol
、
serial baud rate
、
speed dome position setting.
◆
Position of Dip switch is as below figure.
Dip switch first 1
∼
8 bits for address,9
∼
10 bits for protocol,11
∼
12 bits for
serial baud rate, default value is 9600bps
.
Setting method as below:
This speed dome supports multiple protocol, Protocol setting as below
figure.
◆
Speed Dome Address Setting: Control command includes speed dome
address. Speed Dome only react to the commnad of its own IP address.
Via Dip switches 1~8 to change, not via user inter face. Fixed address
from 1 to 254.
1
ON
2
ON
3
ON
ON
4
ON
5
ON
ON
6
ON
ON
7
ON
ON
ON
8
ON
9
ON
ON
10
ON
ON
......
ID B1 B2 B3 B4 B5 B6 B7 B8
254 ON ON ON ON ON ON ON
When user login IP address, Client S/W will be automatically asked to install.
Before login, please make sure the downloading Active X functions are
permitted to Network security settings, or adjust the security level.
Control settings
:
1. Open IE browser;
2. Download Controls;
3. Select control package to download, and install.
• Input the IP cam address at URL of browser, and User ID and Password.
The default value to login IP speed dome as below. If no ID & Password
requested, just input IP address is ok.
IP 192.168.1.221
ID admin
PW admin
Note 1 : IP address of PC and IP camera should be at same Network
segment.
Note 2 : The proposed setup is complete, change and save securely
the password.
■
Safety Precautions
:
※
Do not attempt to disassemble, in case electric shock. Unless assigned
qualified technician, otherwise, please do attempt for maintenance.
※
The installation should be performed by qualified service personnel shall
comply with all local regulations.
※
Please refer to the appropriate installation safety norms.
※
Please note the requires installation environment of this product.
※
Using a reliable tool, a poor quality tool might cause product damage,
but also personal and property damage.
※
Check before installation. The recommended installation site and intensity
of the strength should be greater than the weight of the IP Speed Dome
and accessories integrated 8 times.
※
Please keep the attached packing materials for future use.
■
Warm
:
※
Prohibit the storage or use of highly flammable, explosive materials in the
danger zone to install and use the product.
※
In the product installation must strictly comply with the national electrical
safety procedures and the use of the region.
※
Confirm the installation process you might come into contact with a fixed
mounting position near the power supply and the power of this product
has been disconnected.
※
Voltage to this product is AC24V, any voltage above this value is prohibitted.
※
This product must not be installed or used in excess of the requirements
of environment.
※
All outlets must have waterproof.
※
Make sure ground wire to ground and resistsance less than 4
Ω
to gain the
best surge protection.
LA
N
1
2
3
1
2
3
24VAC power outlet
Ethernet 10/100M
Ground
2.Full Functional
1.Standard
1
2
3
4
5
6
7
8
L A
N
1
2
3
4
5
6
7
8
Ground
24VAC power outlet
Audio In(White)
Alarm Audio Out(Yellow)
RS485: Blue RS485-, Blue-white RS485+
Ethernet 10/100M
Alarm: Pink : COM
Gray: Alarm Input 1
Red: Alarm Input 2
Black: Alarm Input 3
YellowGreen: Alarm Input 4
Yellow: Alarm Output 1
YellowWhite : Alarm Output 2
BNC(Black)
AC2 4 V
Power Outlet
:
S wit ch Digits
B aud Rat e
〓
1
〓
2
~
〓
9
〓
10
〓
11
〓
12
9600
OFF
ON
S wit ch Num ber
PROTOCOL
PELCO_PD
〓
1
〓
2
~
〓
9
〓
10
〓
11
〓
12
ON
ON
Factory Default:
Note
:
the serial baud rate of both speed dome and Network server should
be the same, default value is preset, Please do not revise. If a revise is
necessary.