Dip Settings

Installation

External Wiring

Login IP camera

Safety Precautions

This sector is for protocol

serial baud rate

speed dome position setting.

 Position of Dip switch is as below figure.

Dip switch first 1

8 bits for address,9

10 bits for protocol,11

12 bits for 

serial baud rate, default value is 9600bps

.

Setting method as below:

This speed dome supports multiple protocol, Protocol setting as below 
figure.

Speed Dome Address Setting: Control command includes speed dome 

   address. Speed Dome only react to the commnad of its own IP address. 
   Via Dip switches 1~8 to change, not via user inter face. Fixed address 
   from 1 to 254.

1

ON

2

ON

3

ON

ON

4

ON

5

ON

ON

6

ON

ON

7

ON

ON

ON

8

ON

9

ON

ON

10

ON

ON

...... 

ID                  B1             B2             B3             B4             B5              B6             B7             B8

254                                 ON            ON             ON            ON            ON             ON            ON           

When user login IP address, Client S/W will be automatically asked to install. 
Before login, please make sure the downloading Active X functions are 
permitted to Network security settings, or adjust the security level.

Control settings

1. Open IE browser;
2. Download Controls;
3. Select control package to download, and install.

•  Input the IP cam address at URL of browser, and User ID and Password. 
   The default value to login IP speed dome as below. If no ID & Password 
   requested, just input IP address is ok.

IP         192.168.1.221
ID         admin
PW       admin

Note 1 : IP address of PC and IP camera should be at same Network 
             segment. 
Note 2 : The proposed setup is complete, change and save securely 
              the password.

 Safety Precautions

Do not attempt to disassemble, in case electric shock. Unless assigned 

    qualified technician, otherwise, please do attempt for maintenance.

The installation should be performed by qualified service personnel shall 

    comply with all local regulations.

Please refer to the appropriate installation safety norms.

Please note the requires installation environment of this product.

Using a reliable tool, a poor quality tool might cause  product damage, 

    but also personal and property damage. 

Check before installation. The recommended installation site and intensity 

    of the strength should be greater than the weight of the IP Speed Dome 
    and accessories integrated 8 times.

Please keep the attached packing materials for future use.

■ 

Warm

Prohibit the storage or use of highly flammable, explosive materials in the 

    danger zone to install and use the product.

In the product installation must strictly comply with the national electrical 

    safety procedures and the use of the region. 

Confirm the installation process you might come into contact with a fixed 

    mounting position near the power supply and the power of this product 
    has been disconnected.

Voltage to this product is AC24V, any voltage above this value is prohibitted.  

This product must not be installed or used in excess of the requirements 

    of environment.

All outlets must have waterproof.

Make sure ground wire to ground and resistsance less than 4

Ω

 to gain the

 

  

best surge protection.

LA

N

1

2

3

1
2
3

24VAC power outlet
Ethernet 10/100M
Ground

2.Full Functional

1.Standard

1
2

3
4

5

6

7

8

L A

N

1
2
3
4
5
6
7

8

Ground
24VAC power outlet
Audio In(White)
Alarm Audio Out(Yellow)
RS485: Blue RS485-, Blue-white RS485+
Ethernet 10/100M
Alarm: Pink : COM
           Gray: Alarm Input 1
           Red: Alarm Input 2
           Black: Alarm Input 3
           YellowGreen: Alarm Input 4
           Yellow: Alarm Output 1
           YellowWhite : Alarm Output 2
BNC(Black)  

AC2 4 V

Power Outlet

S wit ch  Digits

B aud Rat e

1

〓 

2

〓 

9

〓 

10 

〓 

11 

〓 

12

9600

OFF

ON

S wit ch  Num ber

PROTOCOL

PELCO_PD

1

〓 

2

〓 

9

〓 

10 

〓 

11 

〓 

12

ON

ON

Factory Default:

Note

the serial baud rate of both speed dome and Network server should 

be the same, default value is preset, Please do not revise. If a revise is 
necessary.