background image

FOR YOUR SAFETY

Read and understand this manual before use.

Keep this manual for future reference.

Wall Mount Wet/Dry Vacuum

Model No. 

VWMB508 0101

Operator’s Manual

Wet/Dry  Vacuum

Distributed By

Cleva North America, Inc.

601 Regent Park Court

Greenville, SC  29607

Replacement Filters & 

Accessories available at:

Vacmaster.com

Summary of Contents for VWMB508 0101

Page 1: ... Keep this manual for future reference Wall Mount Wet Dry Vacuum Model No VWMB508 0101 Operator s Manual Wet Dry Vacuum Distributed By Cleva North America Inc 601 Regent Park Court Greenville SC 29607 Replacement Filters Accessories available at Vacmaster com ...

Page 2: ...ide in producing a high quality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights whi...

Page 3: ...hould has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated surfaces Do not run the vacuum over cord Do not handle...

Page 4: ...ncrease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help SAVE THESE INSTRUCTIONS NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC rules These lim...

Page 5: ... USE AROUND EXPLOSIVE LIQUIDS OR VAPORS CAUTION DO NOT VACUUM DRYWALL DUST OR FIREPLACE SOOT OR ASH WITH STANDARD WET DRY FILTER THIS TYPE OF DUST IS VERY FINE WHICH MAY NOT BE CAPTURED BY THE FILTER AND CAUSE DAMAGE TO MOTOR WHEN VACUUMING FINE DUST USE A FINE DUST FILTER WARNING SERVICING OF DOUBLE INSULATED WET DRY VACUUM WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF INSULATION ARE PROV...

Page 6: ...e injury NOTICE Without Safety Alert Symbol Indicates a situation that may result in property damage EXTENSION CORDS When using an extension cord with your Wet Dry Vacuum refer to the following table to determine the required A W G wire size Before using the cleaner make sure the power cord and extension cord are in good working condition Make repairs or replacements before using the vacuum cleane...

Page 7: ... Rack Hose Storage Support Wall Mount Rack Wire Accessory Rack Vac Assembly Standard Hose Flex Hose Extension Wands Car Nozzle Concentrator Nozzle Crevice Tool Utility Nozzle Remote Control Handle Cartridge Filter Foam Wet Filter Screws Operator s Manual A B C D E F G H I J K L M N O P Q Hose Storage Wall Protector Handle Wire Accessory Storage Accessory Storage Cord Storage Hook Reset Button Wall...

Page 8: ...ace Make sure the buttons on the rod are directed as illustrated Fig 5a 5b 6 Locate the two openings on the bottom of the wall mount rack and insert the wire accessory storage into the wall mount until they lock in place Make sure the wire accessory storage is directed towards the front side of the wall mount rack Fig 6 7 Insert the steel rod with hose storage rack into the two holes located on th...

Page 9: ...n tank and secure into place using the 2 side latches Fig 12 13 4 Mount the vacuum onto the wall mount rack by aligning the hanging hook on the rear of the vacuum with the slot on the wall mount rack and slide downward until it locks Fig 14 5 Wind the excess power cord around the cord storage hook located on the side of the vacuum Fig 15 6 Insert the locking end of the hose into the vacuum port of...

Page 10: ...PPLY INFORMATION ENTITLED IMPORTANT SAFETY INSTRUCTIONS DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES VAPORS OR EXPLOSIVE DUSTS IN THE AIR FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO LIGHTER FLUID SOLVENT TYPE CLEANERS OIL BASED PAINTS GASOLINE ALCOHOL OR AEROSOL SPRAYS EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO COAL MAGNESIUM GRAIN OR GUN POWDER TO REDUCE THE RISK OF HEALTH HAZARDS...

Page 11: ...remove the vacuum from the wall mount rack and put it on the floor The vacuum can be heavy when full of liquids and may be difficult to remove from the rack 1 Verify that the power cord is disconnected from the outlet Make sure that the collection tank is clean and free of dust and dirt Fig 1 2 Remove the cartridge filter then carefully install the foam wet filter over the filter cage and place th...

Page 12: ...mmerse the nozzle completely in the liquid leave a gap at the tip of the nozzle opening to allow air inflow The machine is fitted with a float valve that stops the suction action when the collection tank reaches its maximum capacity You will notice an increase in motor speed When this happens turn off the machine disconnect from power supply and empty the liquid into a suitable receptacle or drain...

Page 13: ...tion Fig 3 5 Fit the desired extension wand and or nozzle to the free end of the vacuum hose Fig 4 6 Verify that the on off switch is in the O OFF position before plugging the power cord into the outlet Fig 5 6 7 Before turning ON the vacuum firmly hold the loose end of the hose Turn the motor on by flipping the switch to the I ON position or set the switch to the remote control setting and use th...

Page 14: ...ded period of time Remove used batteries promptly Batteries must be disposed of in a specified matter to prevent contamination of the environment Before disposing of damaged or worn out batteries contact your local waste disposal agency or the local Environmental Protection Agency for information and specific instructions STORAGE Before storing your vacuum the collection tank should be emptied and...

Page 15: ...terclockwise 2 Carefully remove the cartridge filter by sliding it off the filter cage Fig 6 3 Clean the cartridge filter by gently tapping or brushing dirt off Cleaning should not be done indoors in living areas For optimal performance a new filter is recommended 4 Install cleaned or new filter into place as instructed above 5 Wet filters should be removed and allowed to air dry for 24 hours befo...

Page 16: ...ewdriver remove the screws on the remote control Fig 1 2 Slide back the remote cover so that the white triangle on the remote cover points to the unlock symbol Fig 2 3 3 Remove the remote cover from the handle Fig 4 4 Lift the foam cover to expose the battery and remove the old battery Fig 5 5 Insert the new battery with the terminals in the direction shown and make sure to replace the foam cover ...

Page 17: ...ged Attach or replace the cartridge filter Vacuum has been used to collect fine dust such as dry wall dust fireplace soot or ash without a fine dust filter equipped Remove the standard cartridge filter and install the appropriate fine dust cartridge filter Reduced efficiency and motor speed vibration There is a blockage in the nozzle hose or the collection tank inlets The cartridge filter is clogg...

Page 18: ...18 EXPLODED VIEW 10 1 6 7 3 8 4 9 2 5 3 11 12 13 14 15 16 17 18 19 ...

Page 19: ...1 7 551001179 Hose Storage Support 1 8 551001180 Wall Mount Rack 1 9 551001181 Accessory Storage Rack 1 10 551001141 Foam Wet Filter 1 11 551301101 Cartridge Filter 1 12 551001182 Concentrator Nozzle 1 13 551011109 Utility Nozzle 1 14 551001121 Extension Wand 2 15 551001114 10 ft Flex Hose 1 16 551001113 11 ft Standard Hose 1 17 551170108 Car Nozzle 1 18 551001118 Crevice Tool 1 19 551301102 Remot...

Reviews: