background image

Safety Precautions

For your safety, follow these precautions when using your 

VacMaster

®

 VP545:

  ▪  Read Operator’s Guide carefully before using the machine for 
    the first time.
  ▪  Do not use the VP545 on wet or hot surfaces, or near a heat source.
  ▪  Do not immerse machine or power cord in water or any other liquid.
  ▪  Plug VP545 into grounded power sources only.  

    Do not use extension cord.

  ▪  To disconnect, unplug directly from power source.  Do not disconnect   

    by pulling cord.

  ▪  Do not operate machine with damaged power cord.
  ▪  Only use VacMaster

®

 vacuum pouches and accessories.

  ▪  Do not allow to be used as a toy.  Close supervision is necessary  

 

    when used by or near children.

  ▪  Only use VP545 for its intended use.

Gas Flush System

Products which would be damaged by high pressure must be subjected to a lower 

vacuum or the pressure must be counterbalanced by inflating the bag with inert gas.

The gas flush system is designed to remove the oxygen and replace it with a mixture 

of Carbon Dioxide and Nitrogen to extend shelf life and provide a higher quality 

product to the consumer. This is beneficial when packaging items that shouldn’t be 

compressed. This includes but is not limited to soft fruits, dried foods, chips, pasta, 

and pre-cooked meals. By adding a mixture of Carbon Dioxide and Nitrogen, the food 

will stay fresh longer while keeping its original shape.

How To Use:

Consult your local authorized gas supplier for assistance in buying, regulating, and 

connecting the gas to the machine.

Gas Fill Operating Instructions:

Connect the required gas cylinder, (complete with regulator), to the machine by hose. 

The Regulator may never be set more than atmospheric pressure, approximately 14 

psi. The appropriate level should be between 5 and 12 psi. 

To add gas flush to the normal operating cycle, follow the operating instructions. If 

there is no gas flush time set, there will be no gas flush in the process of sealing. 

To use the gas flush add increments of .1 seconds to the timer. It may take several 

adjustments to get the package to the desired fill level.

Summary of Contents for VP545

Page 1: ...Operator s Guide VP545 Chamber Machine Commercial Vacuum Packaging System...

Page 2: ...mess The VP545 Chamber Machine uses commercial technology Simply place the pouch to be sealed inside the chamber and close the lid This activates the vacuum pump and the vacuum and sealing process be...

Page 3: ...oil bottle 2 With a phillips screwdriver remove the 4 screws to open the back of the cabinet 3 Locate the oil fill bolt on the top of the vacuum pump 4 Remove oil fill bolt 5 Watching site glass inse...

Page 4: ...gs Several sizes available to meet your packaging needs Terrific for hundreds of applications in and out of the kitchen Safe for freezer refrigeration and microwave use Cook in bags can be boiled Bag...

Page 5: ...only fresh foods Do not package old or rancid foods An already bad product does not improve with vacuum packaging Fresh foods Meats vegetables cheeses etc should be refrigerated at 34 F or below or f...

Page 6: ...oxygen and replace it with a mixture of Carbon Dioxide and Nitrogen to extend shelf life and provide a higher quality product to the consumer This is beneficial when packaging items that shouldn t be...

Page 7: ...in use or while machine is in storage Filler Plates used to take up space in the vacuum chamber Using the plates will result in a faster vacuum time since there is less air to be removed from chamber...

Page 8: ...25 seconds Adjust vacuum accordingly to achieve the vacuum required Gas Flush Press the SET button until the GAS FLUSH indicator lights Adjust the gas flush time by using the or buttons For an initial...

Page 9: ...h seal Note A positive seal will look clear upon inspection If the seal is spotty or incomplete increase the sealing time by 0 2 seconds If the seal is white or milky decrease seal time by 0 2 seconds...

Page 10: ...rom pump When oil is completely drained replace and tighten bolt Dispose of old oil properly according to your local and state regulations 8 Follow the Adding Oil to Vacuum Pump instructions at beginn...

Page 11: ...nspect the brown Teflon tape covering the seal wire If the tape becomes burnt or torn replace Lid gasket make sure gasket and the top of the chamber remains clean and free of debris Troubleshooting No...

Page 12: ...Upper Platen for Lid 1 3 Chamber Lid 1 979501 4 Lid Gasket 1 979202 5 Top Bar 2 979505 6 Seal Pad 2 976598 7 Seal Wire 2 979109 8 Teflon Tape 4 979822 9 Seal Bar 2 10 Brass Contacts 6 11 Seal Bar Tens...

Page 13: ...ument Panel 1 979125 2 Vacuum Gauge 1 979126 3 Circuit Board 1 979127 4 Cover Plate 1 5 Cable Sheath 1 6 Housing Case 1 7 Lid Latch Assembly 1 979170 8 Power Switch Bracket 1 979137 9 Power Switch 1 9...

Page 14: ...licone Tube 1 979156 12 Gas Shock 2 979356 13 Lid Hinge 2 979552 14 Lid Hinge Bracket 2 15 Screw and Nut 1 979357 16 Proximity Switch Seat 1 979354 17 Proximity Switch 1 979355 18 Pull Rod 1 19 Lid Hi...

Page 15: ...Notes...

Page 16: ...and workmanship refund of the purchase price or grant of a reasonable allowance on account of such defects all as set forth above ARY Inc is not responsible for any consequential damages resulting fr...

Reviews: