13
WARNING: TO REDUCE THE RISK OF ELECTRIC SHOCK, UNPLUG BEFORE
TROUBLESHOOTING.
TROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply – cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power
cord. If damaged, have it
repaired by a professional.
3) Collection tank full.
3) Empty collection tank.
Dust comes out from motor
cover.
1) The cartridge filter is missing
or damaged.
1) Attach or replace cartridge
filter.
Reduced efficiency and motor/
speed vibration.
1) There is a blockage in the
nozzle, hose, or the collection
tank inlet. The cartridge filter is
clogged by dry dust.
1) Check nozzle, hose and
c o l l e c t i o n t a n k i n l e t s f o r
blockage. Take off the filter
and clean it or install a new
cartridge filter.