background image

 
 

POLARIZED PLUG 

To reduce the risk of electrical shock, this appliance has a polarized plug (one with the blade wider than the 
other).  This plug will fit in a polarized outlet only one way.  If the plug does not fit fully in the outlet, reverse the 
plug.  If it still does not fit, contact a qualified electrician to install the proper outlet.  Do not change the plug in 
any way.  Double insulation         eliminates the need for the three wire grounded power cord and grounded 
power supply system. 

 

 
 
 

 

 
 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
DRY VACUUMING  

 

WARNING:  

BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY 

INSTRUCTIONS & WARNINGS

’.  DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES, VAPORS, 

OR EXPLOSIVE DUSTS IN THE AIR.  FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT 
LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS, GASOLINE, ALCOHOL 
OR AEROSOL SPRAYS.  EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO; COAL, 
MAGNESIUM, GRAIN OR GUN POWDER.  TO REDUCE THE RISK OF HEALTH HAZARDS FROM 
VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.

 

 

1. Verify that the power cord is disconnected from the outlet.  (fig. 1) 
2. In order to prepare your vacuum for dry vacuuming, verify that the cartridge filter is securely mounted. 
    Make sure the filter is pushed in until it stops against the power head.  (fig. 2) (Your Wet/Dry Vac comes   
    with the cartridge filter pre-installed, if not see page 10 for installation instructions.) 
3. Place filter retainer on top of cartridge filter and tighten down by turning the retainer handle clockwise. 
    (fig. 3)  

 

4. Place the power head back on the container, aligning the top section with the latches, and snap into   
    place.  (fig. 4) 

 

OPERATING INSTRUCTIONS: DRY VACUUMING 

 

5. Insert the locking end of the hose into the vacuum port on the power head and lock in place.  Push the 

required attachment onto the free end of the hose or extension.  (fig. 5)  

6. Plug in the power cord into the outlet.  (fig. 6) 
7. Turn the motor on by fl

ipping the switch to the ‘I’ ON position.  (fig. 7) 

8. Once you have completed vacuuming, f

lip the switch to the ‘O’ OFF position and unplug the power cord 

from the outlet.  

 

O = OFF         I = ON 
 

DO NOT USE THE CARTRIDGE FILTER FOR LIQUID VACUUMING. 

DRY-VACUUM OPERATION 

Summary of Contents for VJC1210PF

Page 1: ...anual 12 Gallon Model No VJC1210PF FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 44 Parkway Commons Greer SC 29...

Page 2: ...day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs or alterations and lack of maintenance Please keep your receipt...

Page 3: ...damaged cord plug or other parts If your Wet Dry Vac is not working as it should has missing parts has been dropped or damaged left outdoors or dropped into water return it to an independent service...

Page 4: ...WARNING SERVICING OF DOUBLE INSULATED WET DRY VACUUMM WITH A DOUBLE INSULATED WET DRY VACUUM TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSU...

Page 5: ...Brush Squeegee I Cartridge Filter J Filter Retainer K Foam Sleeve Filter L 4 Screws Bag M Operator s Manual NOTE The hose and accessories for this vacuum are 2 5 diameter Length of Extension Cord 110V...

Page 6: ...ters are mounted correctly Do not over tighten screw fig 5 6 Your vacuum comes ready for dry vacuum cleaning If cartridge filter is not installed refer to page 10 for filter installation fig 6 7 7 For...

Page 7: ...T DO NOT VACUUM TOXIC MATERIALS 1 Verify that the power cord is disconnected from the outlet fig 1 2 In order to prepare your vacuum for dry vacuuming verify that the cartridge filter is securely moun...

Page 8: ...G 3 Fit the desired nozzle to the vacuum hose fig 3 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 4 5 Turn the motor on by flipping the switch to...

Page 9: ...blowing port on the back side of the power head and lock into position fig 3 6 Fit the desired extension wand and or nozzle to the vacuum hose fig 4 7 Ensure the power switch is turned off and plug in...

Page 10: ...er the filter cage with the flat end of the filter towards the vacuum power head Carefully push filter in until it stops against the power head g 2 3 4 Place filter retainer on top of cartridge filter...

Page 11: ...l not operate 1 No power supply 1 Check power supply cord breakers fuses 2 Faulty power cord 2 Unplug and check the power cord If damaged have it repaired by a professional 3 Container full 3 Empty co...

Page 12: ...12 EXPLODED VIEW AND PARTS...