background image

Distributed By

Cleva North America, Inc.

601 Regent Park Court

Greenville, SC  29607

Replacement Filters & 

Accessories available at:

Vacmaster.com

FOR YOUR SAFETY

Read and understand this manual before use.

Keep this manual for future reference.

3.2Gal / 12L

Model No.

 

VHB305M

Operator’s Manual

Wet/Dry Vacuum

 

Summary of Contents for VHB305M

Page 1: ...t Park Court Greenville SC 29607 Replacement Filters Accessories available at Vacmaster com FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference 3 2Gal 12L Model No VHB305M Operator s Manual Wet Dry Vacuum ...

Page 2: ...gh quality durable product This Vacmaster product carries a limited two 2 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Please keep your receipt as proof of purchase This warranty gives you specific legal rights and you may have other r...

Page 3: ... rain Store indoors If vacuum is not working as it should has been dropped damaged left outdoors or dropped into water return it to a service center Do not unplug by pulling on cord To unplug grasp the plug not the cord Do not use with damaged cord or plug Do not pull or carry by cord use cord as a handle close a door on cord or pull cord around sharp edges or corners Keep cord away from heated su...

Page 4: ...NSULATED WET DRY VACUUM TWO SYSTEMS OF INSULATION ARE PROVIDED INSTEAD OF GROUNDING NO GROUNDING MEANS IS PROVIDED ON A DOUBLE INSULATED APPLIANCE NOR SHOULD A MEANS FOR GROUNDING BE ADDED SERVICING A DOUBLE INSULATED WET DRY VACUUM REQUIRES EXTREME CARE AND KNOWLEDGE OF THE SYSTEM AND SHOULD BE DONE ONLY BY QUALIFIED SERVICE PERSONNEL REPLACEMENT PART FOR A DOUBLE INSULATED WET DRY VACUUM MUST BE...

Page 5: ...e Size More than Not more than 0 6 18 16 16 14 6 10 18 16 14 12 10 12 16 16 14 12 12 16 14 12 Not recommended The following signal words and meanings are intended to explain the levels of risk associated with this product SYMBOL SIGNAL MEANING DANGER Indicates an imminently hazardous situation which if not avoided will result in death or serious injury WARNING Indicates a potentially hazardous sit...

Page 6: ... Contents List Key Description Q t y A Vac Assembly 1 B Hose 1 C Base 1 D Casters 4 E Utility Nozzle 1 F Crevice Tool 1 G Dust Bag 4 H Multi Surface Floor Nozzle 1 I Round Dust Brush 1 J 6 Screws Bag 1 K Extension Wands 3 L Foam Sleeve Filter 1 M Reusable Cloth Filter 1 N Operator s Manual 1 O Wall Mounting Support 1 On Off Switch Vacuum Port Collection Tank Base Caster Handle Blow Port Accessory ...

Page 7: ... of the base Apply pressure until castors snap into place fig 8 9 Turn the collection tank upside down and fit the base assembly onto the tank Secure the base to the tank with the supplied screws Verify that the base is assembled correctly Do not over tighten screw fig 9 10 Place the power head back on the collection tank aligning the top section with the latches and snap into place fig 10 11 11 I...

Page 8: ... IN AREAS WITH FLAMMABLE GASES VAPORS OR EXPLOSIVE DUSTS IN THE AIR FLAMMABLE GASES OR VAPORS INCLUDE BUT ARE NOT LIMITED TO LIGHTER FLUID SOLVENT TYPE CLEANERS OIL BASED PAINTS GASOLINE ALCOHOL OR AEROSOL SPRAYS EXPLOSIVE DUSTS INCLUDE BUT ARE NOT LIMITED TO COAL MAGNESIUM GRAIN OR GUN POWDER TO REDUCE THE RISK OF HEALTH HAZARDS FROM VAPORS OR DUST DO NOT VACUUM TOXIC MATERIALS 13 Align the two s...

Page 9: ...4 See filter installing instructions on page 12 DO NOT USE THE REUSABLE CLOTH FILTER FOR LIQUID VACUUMING DO NOT USE COLLECTION BAG FOR LIQUID VACUUMING OPERATING INSTRUCTIONS WET VACUUMING 3 Fit the desired nozzle to the vacuum hose fig 5 WARNING BE SURE TO READ UNDERSTAND AND APPLY INFORMATION ENTITLED IMPORTANT SAFETY INSTRUCTIONS DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES VAPORS OR EXPLOSIVE ...

Page 10: ...THAT MIGHT BE INHALED CAUTION KEEP BYSTANDERS CLEAR FROM BLOWING DEBRIS 4 Verify that the switch is in the O OFF position before plugging the power cord into the outlet fig 6 5 Turn the motor on by flipping the switch to the I ON position fig 7 6 After use empty the collection tank clean and dry the inside and outside before storage IMPORTANT When vacuuming large quantities of liquids do not immer...

Page 11: ...st filters on hand NOTICE The filter included is made of high quality material designed to stop small dust particles The filter should be used for dry pick up only A dry filter is necessary to pick up dust If the dust filter is wet it will clog quickly and be very difficult to clean Handle the filter carefully when removing it for cleaning and replacing it Check the filters for tears or small hole...

Page 12: ... outlet fig 1 2 Remove power head and place in upside down position Follow instructions to remove cloth filter 3 Carefully slide foam sleeve filter down over the filter cage making sure the whole cage is covered fig 2 3 4 Replace the power head onto the collection tank 1 With the removed power head in the upside down position carefully remove foam sleeve filter fig 4 2 Use a mild soap and water so...

Page 13: ...cord If damaged have it repaired by a professional 3 Collection tank full 3 Empty collection tank Dust comes from motor cover 1 The reusable cloth filter is missing or damaged 1 Attach or replace the reusable cloth filter Reduced efficiency and motor speed vibration 1 There is a blockage in the nozzle hose or the vacuum inlets Or the dust filter is blocked by fine dust 1 Check nozzle hose and inle...

Page 14: ...14 EXPLODED VIEW ...

Page 15: ... 02 01 X1 01 Hook 1 6 VH57PF 20 01 X1 01 Container 1 7 VH57PF 20 02 X1 01 Base 1 8 TVQTJL 12 00 Caster 4 9 V1CT Crevice Tool 1 10 V1UB Utility Nozzle 1 11 FV7822 09 00 18 Hose 1 12 VFF21 Foam Filter 1 13 VRC2 Cloth Filter 1 14 V1RB Round Dust Brush 1 15 V1EW Extension Wands 3 1 16 V1MSFN Multi Surface Floor Nozzle 1 17 VDBT Dust Bag 1 18 FV9201 02 01 X1 01 Mounting Support 1 ...

Reviews: