3. Remove the brush roll by carefully lifting out
.
4. Remove the worn or broken belt.
5. Use scissors to remove any entangled hair around the brush roll. Clean any
debris from the floor nozzle.
6. Loop the new belt around motor shaft and the brush roll.
Brush Roll
Belt
Motor Shaft
1
2
7. Reinstall the brush roll back into the floor nozzle. Place the end cap with the
belt into groove first, and then place the other end cap into the other groove as
shown below. Rotate the brush roll to make sure the belt is installed correctly.
Note:
Make sure the belt is in the middle of the slot as illustrated in the below
picture.
End Cap
End Cap
Groove
Groove
1
2
√