To reduce the risk of electric shock, this 

Pump Accessory has a built-in GFCI 

(Ground Fault Circuit Interrupt) plug with 

a ground connection. The plug must be 

used on a properly-grounded outlet. If the 

plug does not fi t into the outlet, contact a 

qualifi ed electrician to install the proper 

outlet. Do not modify the plug in

any way.

After you plug the power cord into the 

outlet, you should always test the GFCI. 

Press the red “RESET” button to reset your 

Pump Accessory. This has to be done each 

time the pump accessory is plugged into 

an outlet. If the red “RESET” indicator does 

NOT pop up, your unit is not functioning 

properly and you should contact an 

Independent Service Center to have your 

Pump Accessory serviced. Once you have 

plugged the power cord into the outlet and 

the tested GFCI, you are ready to run your 

pump.

NOTE: The Pump Accessory should not be 

operated on the same circuit as the 

Wet/Dry Vac.

WARNING: To reduce the risk of fire or explosion, do not operate this vac in 

areas with flammable gases, vapors, or explosive dust in the air. Flammable 

gases or vapors include but are not limited to; lighter fluid, solvent type 

cleaners, oil-base paints, gasoline, alcohol, or aerosol sprays. Explosive 

dusts include but are not limited to; coal, magnesium, aluminum, grain, 

or gun powder. Do not vacuum explosive dust, flammable or combustible 

liquids, or hot ashes. Do not use this vac as a sprayer. To reduce the risk of 

health hazards from vapors or dusts, do not vacuum toxic materials. Store 

Pump Accessory indoors. Do not submerse pump or power cord.

!

WARNING: 

The operation of any utility vac can result in foreign objects being blown 

into the eyes, which can result in severe eye damage. Always wear safety eyewear 
complying with ANSI Z87.1 (or in Canada, CSA Z94.3) before starting operation. Safety 
eyewear is available at many local retail stores.

!

CAUTION: To reduce risk of hearing damage, wear ear protectors when using 

the vac for extended hours or when using it in a noisy area.

TEST 
Button

RESET 
Button

GFCI (Ground Fault 
Circuit Interrupt) Plug

RESET

TEST

Summary of Contents for PE401

Page 1: ...PE401 FOR YOUR SAFETY Read and understand this manual before use Keep this manual for future reference www vacmaster com Cleva North America 601 Regent Park Court Greenville SC 29607 3084514 Conforms to UL Standard 1017 Certified to CSA STD C22 2 No 243 10 ...

Page 2: ...roducing a high quality durable product This Vacmaster product carries a limited one 1 year warranty against defects in workmanship and materials from date of purchase under normal household use If product is to be used for commercial industrial or rental use a 90 day limited warranty will apply Warranty does not apply to defects due to direct or indirect abuse negligence misuse accidents repairs ...

Page 3: ...mping flammable or combustible liquids gases or explosive dusts such as gasoline or other fuels lighter fluid cleaners oil based paints natural gas hydrogen coal dust magnesium dust grain dust or gun powder Keep cord away from heated surfaces Do not expose to rain For indoors use only Do not unplug by pulling on cord To unplug grasp the GFCI Ground Fault Circuit Interrupt plug not the cord Do not ...

Page 4: ...e the following warnings that appear on the motor housing of your Pump Accessory and GFCI housing WARNING FOR YOUR OWN SAFETY READ AND UNDERSTAND OPERATOR S MANUAL DO NOT RUN UNATTENDED DO NOT PICK UP HOT ASHES COALS TOXIC FLAMMABLE OR OTHER HAZARDOUS MATERIALS DO NOT USE AROUND EXPLOSIVE LIQUIDS OR VAPORS WARNING To reduce the risk of electrocution complete the following steps 1 Plug in receptacl...

Page 5: ... the adapter must be connected to a permanent ground such as a properly grounded outlet box cover Whenever the adapter is used it must be held in place by a metal screw Please consult a qualified electrician if there is question how to connect to a ground with a 2 prong outlet The pump should not be plugged into this outlet if it is not grounded WARNING Risk of electric shock This pump is supplied...

Page 6: ...elf with the following product and features and read the entire owner s manual for specific usage of your new Pump Accessory IMPORTANT NOTE Please Read This Manual Carefully Getting to Know Your Pump Pump Accessory Pump Outlet Drain Cap GFCI Plug Pump Inlet Cord Shut off Valve ON OFF Switch Adapter Strainer Familiarize yourself with the control and features of your Pump Accessory before operating ...

Page 7: ...igned to prohibit rotation of the pump after installation so proper alignment must be achieved before the coupler has been tightened 3 After the pump assembly is securely attached to the drain the shut off valve should be installed to the outlet of the pump and turned to the closed position Without this shut off valve installed liquid will leak through the pump outlet Connect a standard size garde...

Page 8: ...educe the risk of fire or explosion do not operate this vac in areas with flammable gases vapors or explosive dust in the air Flammable gases or vapors include but are not limited to lighter fluid solvent type cleaners oil base paints gasoline alcohol or aerosol sprays Explosive dusts include but are not limited to coal magnesium aluminum grain or gun powder Do not vacuum explosive dust flammable ...

Page 9: ...nded liquid until your Wet Dry Vac stops picking up the liquid or until all liquid is cleaned up 3 Turn your vac off allowing it to stop completely Position hose to the desired location to empty drum 5 To verify drum is mostly empty unplug the pump and vac remove vacuum powerhead and inspect the drum contents If liquid is still in drum see Troubleshooting section on page 11 NOTE Do not run pump dr...

Page 10: ...cloth dampened with warm water and mild soap Remove any excess water or debris with a dry cloth Cord Storage Wrap the cord up and use the attached hook loop strap to retain the cord Storing the Pump Accessory When not in use store your Pump Accessory in a cool dry location with the cord wrapped up using the supplied hook loop cord wrap The original Wet Dry Vac drain cap should then be installed on...

Page 11: ...let does not exceed 50 feet 1 Check GFCI see page 8 2 Make sure Pump Accessory is plugged in 3 Make sure switch is on 4 Check house circuit breaker fuse 1 Check fit on adapter 2 Check coupler fit and O ring 3 Check shut off valve fit and O ring 4 Check garden hose fit and make sure hose washer is in place 1 Unplug Pump Accessory 2 Check for blockage 3 If Pump Accessory continues to have an electri...

Page 12: ...1 7 PA01BZ 20 60 Owner s Manual 1 WARNING To reduce the risk of injury from electrical shock unplug power cord before servicing the Wet Dry Vac Pump Accessory 1 2 3 4 5 6 7 REPAIR PARTS PE401 Wet Dry Vac Pump Accessory Always order by part number not by key number Always mention the model number when ordering parts The model number is found on the serial plate located on the pump To order parts ca...

Reviews: