VACITUP 223100 User Manual Download Page 6

 

www.vacitup.se

 

 

Product Description

 

Product designation

 

Central vacuum cleaner 

 

Model

 

Optimuum 3/4/5,5 kW 

 

Description

 

Central vacuum cleaner consisting of a vacuum pump, an electrical cabinet, a 
cyclonic separator with filter and a steel stand. Models denoted with the letter 
F are also equipped with a frequency inverter. 

 

The central vacuum cleaner is mainly made of iron and is painted with powder 
coating. 

 

The vacuum pump is made of aluminium and cast iron. 

 

Environment

 

A great importance has been put on the choice of material and the production 
methods during the design of the central vacuum cleaner. It is worth noting 
that 98% of the machine is recyclable. The remaining portion is made of 
electrical components. No solvents are used during the coating, neither for 
cleaning nor coat mixture. 

 

Material 

 

Stand 

Iron, quality SIS 1312 

 

Cyclone 

Iron, quality SIS 1312 

 

Vacuum pump 

Pump, impeller and stator of aluminium and/or cast iron. 

 

 

Engine shaft of iron. 

 

 

Electrical windings of copper. 

 

Filter 

End plates of metal or plastic. 

 

 

Filter material of cellulose or polyester. 

 

Electrical cabinet 

Cabinet of iron. 

 

 

Components of plastic and copper. 

 

Plastic details 

Polyethylene and Bakelite. 

 

Paint 

Polyester powder, TGIC-free. 

 

Sealing 

Natural rubber. 

 
 

Manufacturer

 

Vacitup AB

 

 

 

Smedvägen 24 

 

 

SE-433 61 Stenkullen 

 

 

Sweden 

 

 

Tel: +46 (0)31 44 32 00 

 

 

Email: [email protected] 

 

 

www.vacitup.se 

 

 

Summary of Contents for 223100

Page 1: ...Vacitup AB Smedv gen 24 SE 433 61 Stenkullen Sweden Tel 46 0 31 44 32 00 info vacitup se www vacitup se USER S MANUAL CENTRAL VACUUM CLEANER 3 4 and 5 5 kW...

Page 2: ...rnings 8 Installation 9 Maintenance and Service 10 Replacement of the Dust Bag 11 Replacement of the Filter 12 Manual Cleaning of the Filter Back Flush 13 Trouble Shooting 14 Service Protocol 15 EC De...

Page 3: ...mage to the machine Read carefully Take the time to read this manual before using the machine for the first time It contains useful information about its installation its functions and its maintenance...

Page 4: ...formed only by trained and authorised staff All instructions in this manual are to be followed for the warranty to be valid Performing an action against recommended instructions will invalidate the wa...

Page 5: ...l Vacuum Cleaner Filter cleaning handle Top of the filter housing Electrical cabinet Cyclone filter housing with filter Lenses for level guard optional Lever to open the dust container Dust container...

Page 6: ...f the central vacuum cleaner It is worth noting that 98 of the machine is recyclable The remaining portion is made of electrical components No solvents are used during the coating neither for cleaning...

Page 7: ...lixon Clixon Clixon Clixon Clixon Airflow m3 h 330 420 330 420 650 Vacuum mbar 280 280 300 300 280 Inlet mm 63 63 63 63 76 Outlet mm 80 80 80 80 80 Filter size m2 4 0 4 0 4 0 4 0 4 0 Filtration BIA Cl...

Page 8: ...cumstances be used for the suction of burning glowing explosive or inflammable fluids or materials 5 If the filter shows any sign of damage it must be replaced before the vacuum cleaner is used in ord...

Page 9: ...quire additional room above the machine 5 The floor must be even and stable enough to carry the weight of the vacuum cleaner 6 The central vacuum cleaner must be anchored to the floor to keep it from...

Page 10: ...pending on use 4 Change the filter if it shows any sign of damage or has a hole 5 Change the dust bag before it becomes too full 6 Check that the cooling air intake to the vacuum pipe is free 7 Check...

Page 11: ...it from being damaged 6 Fit a new dust bag in the dust container and fold the upper edge of the bag around the edge of the dust container 7 Using the handle push the dust container back until it stops...

Page 12: ...e locking ring that hold the top of the filter housing 4 Lift off the top 5 Carefully lift the filter out of the housing so that the dust does not spread out 6 Place the filter upside down on the floo...

Page 13: ...eaner by turning the main switch to the OFF position 4 Wait until the pump has stopped completely which takes approximately 20 seconds 5 Pull the filter cleaning handle again and then push it all the...

Page 14: ...The yellow lamp FILTER is lit on applicable models a Take out and clean the filter Check for damage or holes in the filter If it is damaged the filter must be replaced 4 The red lamp LEVEL is lit on...

Page 15: ...flush function 6 Test and check any discordant sounds from the pump System Rem Missing Done 1 Check vacuum inlets Density and function 2 Check automatic hose hanger Density and function of the valve...

Page 16: ...cuum Cleaner 3 4 and 5 5 kW We declare that the above mentioned products comply with the following European Directives Low Voltage Directive IEC EN 60335 2 69 IEC EN 60335 1 Machinery Directive EN ISO...

Reviews: