Technical Brief:
Vacuum System Design:
Choosing The Correct Sized Tubing
Technical Brief:
How Vacuum Pumps Work
Operating Instructions: VP 00-10-20-80-90 Series Modular Vacuum Pumps – 2
© 2014 Vaccon Company
The recommended tubing sizes are based on polyethylene or polyurethane tubing with 0.062” [ / ”, 1.5 mm] wall thickness
Note: Vaccon discourages the use of quick disconnect fi ngs on all connec ons
VP00
VP20/80/90
VP10
End Views:
Air Supply
Ports
Top Views:
Vacuum
Ports
Operating / Installation Instructions:
VP 00-10-20-80-90
Modular Venturi Vacuum Pump Series
Addi onal Informa on
VP Series
Model
Air Supply Port
Threads
Recommended
Air Supply Line
(outer diameter)
Vacuum Port
Threads
Recommended
Vacuum Line
(outer diameter)
VP00-60 (M,H) Series
10-32 UNC Female
¼"
[6 mm]
10-32 UNC Female
¼"
[6 mm]
VP10-(60,90) (L,M,H) Series
¼
NPT
¼"
[6 mm]
⅛
NPT
¼"
[6 mm]
VP10-(100,150) (L,M,H) Series
¼
NPT
⅜"
[10 mm]
⅛
NPT
⅜"
[10 mm]
VP20-(60,90) (L,M,H) Series
¼
NPT
¼"
[6 mm]
¼
NPT
¼"
[6 mm]
VP20-(100,150) (L,M,H) Series
¼
NPT
⅜"
[10 mm]
¼
NPT
⅜"
[10 mm]
VP80-200 (L,M,H) Series
¼
NPT
⅜"
[10 mm]
⅜
NPT
⅜"
[10 mm]
VP80-250 (L,M,H) Series
¼
NPT
⅜"
[10 mm]
⅜
NPT
½"
[12 mm]
VP90-300 (L,M,H) Series
⅜
NPT
½"
[12 mm]
½
NPT
½"
[12 mm]
VP90-350 (L,M,H) Series
⅜
NPT
½"
[12 mm]
½
NPT
½" [
12 mm]