12 

Steps 

Operation 

Display shows 

Display shows n n 

Press Set/Mute key 

Press Up key, Down key to change parameter to targeted year 

22 

Press Set/Mute key 

Press Set/Mute key 3s to save parameter and quit 

”Month” setting example(other r,s,F,Pt,SCY setting refers to this example) 

Steps 

Operation 

Display shows 

Display shows n n 

Press Up key, Down key to choose settable parameter

y

 

Press Set/Mute key 

Press Up key, Down key to change parameter to targeted month 

Press Set/Mute key 3s to save parameter and quit 

Please finish setting in 2 minutes, it will automatic quit and shows normal if no operation. 

SCY 

sampling period 

Pt 

Printing interval 

year 

month

day 

hour 

min 

Note:  please  do  not  adjust  the  other  values  in  the  manager  menu.  If   values can  not  be  adjusted  properly,  the 
product cannot run normally    
In this case, parameters need to be checked one by one to restore the default value 

5.2.13 Export the USB data 
(1) After  the  USB  flash  disk is  connected  to  the  USB  interface,  the recorder  buzzer beeps  once,  the  digital  tube
displays the upload data code “on” (in case of large amount of data) and the USB flash disk generates the PDF files
on data of current month and last month. After the completion of data transmission, the buzzer beeps once and the
digital tube displays “End”. After 6s, the digital tube returns to normal display.
Note: In case of less data, the digital tube does not display “on” and “end” prompts.
(2) When the USB flash disk is always connected to the recorder module, the data will be imported into the USB
flash disk every other month and the PDF file on the data of current month is generated. When the buzzer beeps
once, the digital tube displays the upload data code “on” (in case of large amount of data). After the completion of
data transmission, the buzzer beeps once and the digital tube displays “End”. After 3s, the digital tube returns to
normal display.
(3) When the USB flash disk is connected to the recorder module and the file is not generated, the PDF files of the
current month and the previous 12 months can be generated manually.

5.2.14 Manually generate PDF files 
When the key is unlocked and no file is being generated, connect the USB flash disk and press the Up key for 3s until 
the digital tube displays “d01”.   

Summary of Contents for VS50

Page 1: ...keep it for future reference The design and speci cations are subject to change without prior notice for product improvement Consult with your dealer or manufacturer for details PHARMACY REFRIGERATOR...

Page 2: ...ries 6 3 PRODUCT OVERVIEW 7 4 TECHNICAL SPEC 7 5 OPERATION 8 5 1 Opera on and display panel 8 5 2 Key opera on 9 5 3 Noise Inside the Unit 13 5 4 ALARM 13 6 CLEANING 14 6 1 Cleaning the Interior and t...

Page 3: ...building in clear of obstruction WARNING Do not use mechanical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer WARNING Do not damage the r...

Page 4: ...r more must be used and copper core conductors in the wall connected to the power socket must also have a cross sectional area of 4mm2 or more This series of products are strictly prohibited to put in...

Page 5: ...socket are plugged firmly and reliably otherwise it may lead to fires When unplugging from the power socket hold the power plug firmly and remove it Do not pull the wires of the power plug directly If...

Page 6: ...he insulation and cause leakage or electric shock Do not insert metal objects such as nails or wires into any openings and gaps of the Pharmacy Refrigerator or into any vent used for internal air circ...

Page 7: ...at both sides 15 cm at the rear and 20 cm at the top of the unit This will allow cold air to circulate around the Pharmacy Refrigerator and improve the efficiency of the cooling process The Pharmacy R...

Page 8: ...to the operation instructions below for details 4 Set parameter of cabinet temperature high low temperature alarm deviation etc according to actual need Default temperature setting is 5 C high temper...

Page 9: ...Model number VS50 External dimensions W D H mm 485 450 550 Effective volume 42L Door body Transparent glass door Foaming agent Cyclopentane Cooling mode Air cooling circulation Shell plate Inner Plat...

Page 10: ...on Button Locked off Button unlocked Power failure on Power off off Power on Printer disabled on Printer working off Printer not working Door heat disabled on Door heat working off Door heat not worki...

Page 11: ...locked if there is no operation for 60s or Up key and Down key are pressed for 3s at the same time b When the key is locked only ambient temperature can be checked and Mute key and Light switch key c...

Page 12: ...Lower deviation on low temperature alarm 0 0 10 0 0 cancel the alarm 3 n Check the current date year y Check the current date month r Check the current date day S Check the current date hour F Check t...

Page 13: ...o 1 Every time the door is opened and closed it will be heated for T9 minutes If the door is opened and closed again during the heating period the heating time will be reset Door heating mode P1 is se...

Page 14: ...eps once the digital tube displays the upload data code on in case of large amount of data and the USB flash disk generates the PDF files on data of current month and last month After the completion o...

Page 15: ...bient temperature alarm value tH1 sensor is normal and not shielded then the buzzer will alarm and the digital tube will flash the high ambient alarm code H2 alternately at the interval of 3 seconds e...

Page 16: ...fied technician for assistance 7 MAINTENANCE 7 1 Care When Handling Moving Your Unit Hold the unit around its sides or base when moving it Under no circumstances should it be lifted by holding the edg...

Page 17: ...t heat during operation specially in summer this is caused by the radiation of the condenser and it is a normal phenomenon Condensation condensation phenomenon will be detected on the exterior surface...

Page 18: ...16 REQUESTING ASSISTANCE OR SERVICE If you have any doubt or extra assistance please call Customer Service Vacc Safe Telephone 1300 459 140...

Reviews: