3. The internal main body of the Model VA-2000 SVRS unit is not designed for field
repairs. The unit must be routinely tested as detailed herein, and a unit not operating
properly should be reported immediately. The following external parts may need
replacement over time depending upon environmental exposure and use:
a. Vacuum Gauge (0” to 30” Hg)……………....………….….….VA-2680
b. Adjustment Screw Security Cap………………………….……VA-2900
c. Security Cap Key (Hexagonal Spanner Tool)…………….……VA-2970
d. End Cap Vent Screen…………………………………………..VA-2850
e. Check Valve Spring (Suction Lift @ 3.5 lb)…………………...VA-2320-3.5
f. Check Valve Spring (Submerged Suction @ 0.25 lb)……….....VA-2320S-.25
g. Check Valve Poppet (Suction Lift – Vented)……………...…..VA-2870L-P
h. Check Valve Poppet (Submerged Suction – Non-Vented)...…..VA-2875S-P
To order any of the above parts, call your local pool service company, or call
Vac-Alert
TM
Customer Service for referral to your nearest dealer.
4. The Model VA-2000 SVRS unit should always operate in a dry state. Any indication
that the unit is flooded or water logged, as evidenced by water leakage from the SVRS
unit, requires immediate service attention.
Immediately shut down the pool or spa,
and call your local licensed service company, or call Vac-Alert
TM
Customer Service
for referral to your nearest dealer.
5. The Model VA-2000 meets or exceeds the twelve hour -40 F & +140 F temperature
performance testing set by the ASME/ANSI A112.19.17-2010 Standard for
Manufacturing Safety Vacuum Release Systems. We strongly suggest that the VA-
2000 not be left in below freezing temperatures where the circulation system is not
continually running or not protected by a pump house. In such cases, condensation
could freeze piping and ice may impair or disable the safety features of the VA-2000.
For installations that require winterization, the Model VA-2000 should be removed
and stored, and then re-installed upon system start-up.”
FOR CUSTOMER SERVICE IN FLORIDA & U.S. EAST COAST CALL:
1-877-978-0130
FOR CUSTOMER SERVICE IN ALL OTHER U.S. AREAS CALL:
1-800-374-7405
Dated: April 29, 2011