background image

E

N

G

L

IS

H

7

IMPORTANT INFORMATION

For any installation problem please contact our Customer
Serviceat the 39-0172.812411 operating Monday to
Fridayfrom 8:30 to 12:30 and from 14:00 to 18:00

V2 reserves the right to make modifications to the product
without any prior warning; furthermore, the company 
declines all responsibility for damages to people or property
resulting from improper use or incorrect installation.

Read the following instruction manual thoroughly 

prior to proceeding with installation and programming of
the system.

• This instruction manual is intended solely for use by technical 

staff, qualified in the field of installation of automation devices

• None of the information contained in the manual is of interest 

or use to end users.

• All maintenance or programming operations should be 

conducted exclusively by qualified staff.

The installation, testing and commissioning of door and gate
automation devices should be performed by qualified and skilled
personnel, who must assume responsibility for setting up the
tests envisaged depending on the risks present; and verify
compliance in accordance with legal and regulatory requirements.

• V2 accepts no responsibility for injuries and damage resulting 

from improper use of the product; other than that described in 
this manual.

• Packing materials must be disposed of in full compliance with 

local regulations.

DECLARATION OF CONFORMITY

The undersigned representing the following manufacturer:

V2 S.p.A.

Corso Principi di Piemonte 65, Racconigi (CN), ITALY

herein declares that the product 

WES

is in compliance with the provisions of the following community
directives (including all applicable amendments)

99/5/CE

Directive regarding radio equipment and telecommunication
terminal equipment and reciprocal recognition of their conformity

98/37/CE

concerning the harmonisation of legislation from member states
regarding machinery

and that the technical standards indicated below have been applied:

EN 301 489-3: 2002 

Electromagnetic compatibility and questions relating to the
radiofrequency spectrum (ERM); electromagnetic compatibility
(EMC) standards for radio equipment and services. 
Part 3: specific conditions for short range devices (SRD) operating
between the frequencies of 9 kHz and 40 GHz.

EN 300 328-1: 2001

Electromagnetic and radio spectrum compatibility (ERM);
Broadband transmission systems. Data transmission equipment
operating in the ISM band at 2.4 GHz using broad spectrum
modulation techniques.

EN 12978 : 2003

Industrial, commercial and garage doors and gates - Safety devices
for motorised doors and gates - Test methods and requirements

Racconigi, 12/10/2009
V2 S.p.A. Legal Representative 

Cosimo De Falco

TECHNICAL INFORMATION

DESCRIPTION

WES (Wireless Edge System) is the new V2 system allowing safety
edges to be controlled by radio. 
The system consists of a base unit connected directly to the
control unit, and one or more sensors (up to 8 per base unit)
connected to the safety edges.

The base unit is powered from the control unit and constantly
monitors the status of the sensors connected.
Up to a maximum of 8 sensors may be connected to each base
unit. 
The system is compatible with standard safety edges with NC
breakers, resistive safety edges (8k2).

The system is compatible with all control unit models.

System operation

The system operates independently of the status of the control
unit. The relay corresponding to each sensor unit is kept closed if
no edges are activated.
If an edge is pressed, the relay opens, signalling the anomaly to
the control unit. 
The base unit communicates with each sensor every 15 seconds,
so as to verify their presence and function.

Base

Power supply:

12 / 24 Vdc-ac

Input power:

0,75 W

Dimensions:

125x56x23 mm

Operating temperature:

-20/+60 °C

Outputs (relay switch):

2 edge alarms
1 low battery warning

Number of sensors:

until 8

Number of radio channels:

16

Summary of Contents for WES-BASE

Page 1: ...IL CONTROLLO VIA RADIO DELLE COSTE DI SICUREZZA RADIO CONTROL SYSTEM FOR SAFETY EDGES SYST ME POUR LE CONTR LE PAR RADIO DES BARRES PALPEUSES DE S CURIT SISTEMA PARA EL CONTROL V A RADIO DE LAS BANDAS...

Page 2: ......

Page 3: ...armonisation of legislation from member states regarding machinery and that the technical standards indicated below have been applied EN 301 489 3 2002 Electromagnetic compatibility and questions rela...

Page 4: ...d with UNIT 1 and UNIT 2 respectively The BAT LOW output breaker NC opens when a sensor indicates the low battery status PLEASE NOTE UNIT 1 and UNIT 2 are used to manage 2 edge units in different mode...

Page 5: ...n safety input OUT1 Unit 1 edge input OUT2 Unit 2 edge input BAT LOW Can be used to indicate low battery level START Photocell TX supply BASE UNIT ELECTRICAL CONNECTIONS DIP SWITCHES The device has 8...

Page 6: ...hen proceed as follows To associate an edge with unit 1 proceed as follows 1 Press the PROG button on the base unit once the ALARM LED emits single flashes 2 Press and hold the sensor SET button until...

Page 7: ...lashes depending on the unit being configured button pressed once twice or three times Slow flashing during network deletion button pressed and held down Off Off Off CONDITION GREEN LED RADIO RED LED...

Page 8: ...OW LEDs off The system is operating normally If the control unit does not show that the edge input has been closed there is a connection problem broken wire 4 Observe the LED for a sensor Is the LED o...

Reviews: