TRANSMITTER DATA STORAGE

m

 

CAUTION

: The data storage of the first transmitter 

determines the direction of motion of the motor.

To store a transmitter on a virgin control untit proceed as 
follows:
1.

  Supply power only to the control unit to be programmed

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN key until the LED 1 lights up with solid 

light and the others flash.

4.

  Press the UP+DOWN keys until the motor starts to move in 

one direction

5.

  Release the keys, the motor stops

6.

  Press the UP or DOWN keys according to the direction in 

which the roll-up shutter was moving before it stopped: 

 

-  if the roll-up shutter was being raised press the UP key; 

direction obtained: the UP key raises the roll-up shutter, 
the DOWN key lowers the roll-up shutter

 

-  if the roll-up shutter was being lowered press the DOWN 

key; direction obtained: the DOWN key lowers the roll-up 
shutter, the UP key raises the roll-up shutter.

7.

  To exit the programming mode press the STOP key

8.

  Try to operate the roll-up shutter and verify that it works 

according to the logic described above. If the logic is reversed 
it is necessary to delete all the codes stored (see “DELETION 
OF ALL MEMORIZED TRANSMITTERS”) and repeat the steps 
above.

To add other remote controls follow steps 6, 7, 8 of the 
procedure “RAPID TRANSMITTER DATA STORAGE”

DELETION OF ALL MEMORIZED 
TRANSMITTERS

To delete all codes stored with an Artemis proceed as 
follows:
1.

  Supply power only to the control unit to be programmed

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN keys until the LED 3 lights up with solid 

light and the others flash

4.

  Press and hold down the UP+DOWN keys until the motor 

moves in both directions which confirms the correct deletion 
of the codes.

5.

  Release the keys

6.

  To exit the programming mode press the STOP key

To delete all codes NOT stored with an Artemis proceed as 
follows:
1.

  Cut the power to the motor on which to delete all the codes

2.

  Activate the ARTEMIS programming

3.

  Press the UP or DOWN keys until the LED 3 lights up with solid 

light

4.

  Press and hold down the UP+DOWN keys

5.

  Power the motor and wait until the motor moves in both 

directions wich confirms the correct deletions of the codes

6.

  To exit the programming mode press the STOP key

ADVANCED PROGRAMMING

To perform ADVANCED programming it is necessary to activate 
the programming by following one of the following procedures.

ACTIVATION OF PROGRAMMING

 

Artemis with 1 channel: 

 

•  Press the STOP+UP+DOWN keys until the 6 LEDs light up

 

•  Release the keys: the programming remains active for 30 

seconds during which the LEDs flash

 

Artemis with 2 channels: 

 

•  Press the STOP+UP+DOWN keys of the channel to be 

programmed until the LEDs light up

 

•  Release the keys: the programming remains active for 30 

seconds during which the LEDs flash

 

Artemis with 6 channels: 

 

•  Select the channel to be programmed with the C key

 

•  Press the STOP+UP+DOWN keys until the 6 LEDs light up

 

•  Release the keys: the programming remains active for 30 

seconds during which the LEDs flash

Note: this procedure will be the same for the programming 
of all functions and will not be repeated in the following 
paragraphs

List of available functions:

1.

  Transmitter memorization and sunshade/roll-up shutter mode 

selection

2.

  Deletion of all memorized transmitters 

3.

  Programming the wind sensor intervention threshold 

4.

  Programming the sun sensor intervention threshold 

5.

  Programming the temperature level 

Summary of Contents for LEX-RM

Page 1: ...ECEIVER F MOTOR DUCTEUR TUBULAIRE 45 MM AVEC FIN DE COURSE M CANIQUE ET R CEPTEUR RADIO E MOTORREDUCTOR TUBULAR 45 MM CON FINAL DE CARRERA MEC NICO Y RECEPTOR DE RADIO INCORPORADO P MOTORREDUTOR TUBUL...

Page 2: ...fino a For motors with torque up to Pour moteurs avec couple jusqu Para motores con par de hasta Para motores com bin rio at F r Motoren mit Drehmoment Voor motoren met een koppel tot 30 Nm code 16284...

Page 3: ...3 Fig 4 Fig 3...

Page 4: ...utro 3 MARRONE Fase BROWN Phase MARRON phase MARRON Fase 4 NERO Pulsante BLACK External switch NOIR touche NEGRO Pulsador 5 GIALLO VERDE Terra YELLOW GREEN Ground JAUNE VERT terre AMARILLO VERDE Tierr...

Page 5: ...WHITE Neutral BLANC neutre BLANCO Neutro 3 NERO Fase BLACK Phase NOIR phase NEGRO Fase 4 ROSSO Pulsante RED External switch ROUGE touche ROJO Pulsador 5 VERDE Terra GREEN Ground VERT terre VERDE Tier...

Page 6: ...230V 35 20 15 230 50 145 4 22 660 LEX RM30 230V 55 30 15 230 50 191 4 22 660 LEX RM40 230V 80 40 15 230 50 198 4 22 660 LEX RM50 230V 95 50 12 230 50 205 4 22 660 LEX RM20 120V 35 20 19 120 60 276 4...

Page 7: ...re installing the drive remove any unnecessary cords and disable any equipment not needed for powered operation For installation for awnings a horizontal distance of at least 0 4 m is to be maintained...

Page 8: ...nsors function at least one transmitter must be stored mIMPORTANT Anemometer causes inhibition of functioning of both radio transmitter and external push button for ca 8 minutes The anemometrical sens...

Page 9: ...trol unit it is necessary using a remote control previously stored and proceed as follows 1 Power only the control unit to be programmed 2 Multichannel transmiter only press several times the button S...

Page 10: ...ter until shown by leds the channel stored 2 Position the roll up shutter at the mid height 3 Press the key STOP and immediately after the key DOWN keeping pressed the key STOP until the motor moves f...

Page 11: ...Artemis with 6 channels Select the channel to be programmed with the C key Press the UP DOWN keys until the motor starts to move in one direction 3 Release the keys the motor stops 4 Press the UP or...

Page 12: ...ess and hold down the UP DOWN keys until the motor moves in both directions which confirms the correct deletion of the codes 5 Release the keys 6 To exit the programming mode press the STOP key To del...

Page 13: ...ht up with solid light and the others flash 4 Press the UP DOWN keys until the motor moves in jerks which confirms it is entering the programming phase The number of jerks made by the motor correspond...

Page 14: ...he control unit controlling the tubular motor QUICK STORAGE OF THE TRANSMITTER mCAUTION the first transmitter recorded determines the direction of the motor s movement mCAUTION If the sunshade has a c...

Page 15: ...ition the roll up shutter at mid height using UP STOP DOWN 5 Press and hold down the PROG button of the remote control until the motor starts to move in a direction 6 Release the PROG button the motor...

Page 16: ...motor displays again the set level and exits 9 To exit the programming mode wait for the led to switch off or press key 1 to exit immediately PROGRAMMING OF THE LEVEL OF TEMPERATURE The temperature c...

Page 17: ...heck that it works with the logic above described If the logic is reversed it is necessary to delete all the codes stored read Switch 3 and start again the above procedure To add another transmitter T...

Reviews: