background image

ENGLISH

28

ADJUSTING THE OPERATING TIME

To alter the motor operating time, proceed as follows:

1.

Press and hold the MENU button for at least 2 seconds: the LEDs display the status of the various
functions

2.

Within 10 seconds, press the MENU button for at least 2 seconds: the LEDs come on showing the
operating time set (20 seconds by default)

3.

Press the MENU button briefly to alter the operating time. Each time the button is pressed, the time is
increased up to a maximum of120 seconds, subsequent pressing restarts the time from a minimum
value of 10 seconds

4.

To exit from the programming menu, wait for 12 seconds: the main control unit returns to standby
mode, storing the new settings

STEP

start

up

open

stop

auto

down

photo

edge

dm

fire

canc

light

motor

test

error

1

2s < T < 5s

2

2s < T < 5s

10s

15s

20s

30s

45s

60s

90s

120s

3

T < 1s

Summary of Contents for Easy4

Page 1: ...3 4 CENTRALE DI COMANDO ANALOGICA PER SERRANDE AVVOLGIBILI I ANALOG CONTROL UNIT FOR ROLLER SHUTTERS GB ARMOIRE DE COMMANDE ANALOGIQUE POUR STORES F CUADRO DE MANIOBRAS ANAL GICO PARA PERSIANAS ENROLL...

Page 2: ......

Page 3: ...TIMER 22 CASE WITH KEYPAD 22 CABLE GLAND ASSEMBLY 23 DISPLAYING THE SET FUNCTIONS 24 ALTERING THE FUNCTIONS 25 FUNCTION TABLE 26 ADJUSTING THE OPERATING TIME 28 ADJUSTING THE PAUSE TIME 29 ADJUSTING...

Page 4: ...low voltage wires used for accessories connection this way in case of accidental detachment of a conducting wire dangerous voltage parts will not come into contact with safety low voltage ones The pl...

Page 5: ...nitoring the inputs using LED Operating logic and working times that can be programmed using the programming key and 8 LEDs Possibility of operating in DEAD MAN mode Fitted 433 92 MHz radio receiver P...

Page 6: ...WARNING Normally closed inputs STOP L2 PHOTOCELL L5 EDGE L6 FIRE L7 if not used must be bridged through the COMMON terminal WARNING a wrong connection of the antenna compromises seriously the RADIO w...

Page 7: ...When the FIRE contact is opened the door is opened and cannot be closed again until the contact is reset TRANSMITTER RECEIVER L6 BLACK CABLE L8 BLUE CABLE BLUE CABLE L9 BLACK CABLE L10 BROWN CABLE L1...

Page 8: ...es with external keypads accessory codes 171224 171226 To use the keypad buttons it is essential to install adapter 171226 as shown in the figure Alternatively the WES EASY accessory may be installed...

Page 9: ...easy break housings The type of cable gland is indicated in the figure PLEASE NOTE Remove the electronic circuit board before drill the casing Drill the container using a suitably sized cutter accordi...

Page 10: ...MMING MODE displaying the status of the functions please refer to the FUNCTIONS TABLE start up open stop auto down photo edge dm fire canc light motor test error DISPLAYING THE SET FUNCTIONS Besides d...

Page 11: ...top auto down photo edge dm fire canc light motor test error 1 2s T 5s 2 T 1s 3 2s T 5s 4 When the status of the function has been altered press the MENU button briefly to select the next function to...

Page 12: ...P CLOSE STOP OPEN operational cycle AUTOMATIC LOGIC The start command activates an OPEN PAUSE CLOSE STOP operational cycle Closure starts automatically after the pause time set 4 photo PHOTOCELL INACT...

Page 13: ...the UP or DOWN button is pressed the action of STOP is to stop motion and on its release the motor DOES NOT MOVE UNTIL THE UP or DOWN INPUT IS RELEASED AND PRESSED ONCE MORE PLEASE NOTE when the Man P...

Page 14: ...set 20 seconds by default 3 Press the MENU button briefly to alter the operating time Each time the button is pressed the time is increased up to a maximum of120 seconds subsequent pressing restarts t...

Page 15: ...ol unit returns to standby mode storing the new settings STEP start up open stop auto down photo edge dm fire canc light motor test error 1 2s T 5s 2 2s T 5s 2s T 5s 180s 120s 90s 60s 45s 30s 20s 15s...

Page 16: ...y light while the door is moving UP DOWN STOP COURTESY LIGHT MEMORISING REMOTE CONTROL UNITS 1 Press the MENU button briefly 2 The control unit activates the radio acquisition phase the LEDs come on r...

Page 17: ...the need for direct access to the main control unit To activate this procedure at least one remote control unit must already be memorised with the main control unit Proceed as follows 1 Simultaneousl...

Page 18: ...act is closed Start aborted due to pressed edge detection Edge test is failed 6 dm fire On the fire terminal the contact is open On the fire terminal the contact is closed Start aborted due to fire al...

Page 19: ......

Page 20: ...V2 S p A Corso Principi di Piemonte 65 67 12035 RACCONIGI CN ITALY tel 39 0172 812411 fax 39 0172 84050 info gatestore co uk www remotecontrolgates co uk...