ENGLISH
29
ADJUSTING THE PAUSE TIME
To alter the motor pause time, proceed as follows:
1.
Press and hold the MENU button for at least 2 seconds: the LEDs display the status of the various functions
2.
Within 10 seconds, press the MENU button for at least 2 seconds: the LEDs come on showing the
operating time set (20 seconds by default)
3.
Within 10 seconds, press the MENU button for at least 2 seconds: the LEDs come on showing the pause
time set (30 seconds by default)
4.
Press the MENU button briefly to alter the pause time. Each time the button is pressed, the time is
increased up to a maximum of 180 seconds, subsequent pressing starts the time again from a minimum
value of 15 seconds.
5.
To exit from the programming menu, wait for 12 seconds: the main control unit returns to standby
mode, storing the new settings
STEP
start
up
open
stop
auto
down
photo
edge
dm
fire
canc
light
motor
test
error
1
2s < T < 5s
2
2s < T < 5s
2s < T < 5s
180s
120s
90s
60s
45s
30s
20s
15s
3
T < 1s
ADJUSTING THE COURTESY LIGHT OFF DELAY
When the main control unit returns to standby mode after an operational cycle, the courtesy light remains
on for a programmable length of time up to 5 minutes. The off delay may only be set if the output is set as
the courtesy light (function 7 – please refer to the FUNCTION TABLE).
To alter the courtesy light off delay, proceed as follows:
1.
Press and hold the MENU button, ignoring the virtual dip switch display on the LEDs
2.
After 5 s the LEDs are switched off and the courtesy light switched on
3.
Continue holding the MENU button for the period of time it is desired to set
4.
Release the MENU button. The courtesy light is switched off and the length of time for which it was on is
stored as the off delay