E
N
G
L
IS
H
26
FUNCTION TABLE
(the highlighted boxes indicate the factory default settings)
FUNCTION
(LED)
LED OFF
LED ON
1. start/up
START/STOP LOGIC
The START/UP input controls the STEP
or AUTOMATIC operational cycle based
on the programmed operational logic.
The DOWN input is inactive
UP/DOWN LOGIC
The START/UP input always controls opening
and the DOWN input always controls closing,
independently of the operational logic
programmed.
UP + DOWN when pressed simultaneously is the
same as a STOP command
2. open/stop
START INACTIVE WHILE OPENING
During opening, the START command
is ignored
START ACTIVE WHILE OPENING
During opening, the START command
interrupts opening (no timer is set for automatic
re-closure)
3. auto/down
STEP LOGIC
The start command activates an
OPEN-STOP-CLOSE-STOP-OPEN
operational cycle
AUTOMATIC LOGIC
The start command activates an
OPEN-PAUSE-CLOSE-STOP operational cycle
Closure starts automatically after the pause
time set
4. photo
PHOTOCELL INACTIVE WHILE
OPENING
Photocell intervention during opening is
ignored
PHOTOCELL ACTIVE WHILE OPENING
Photocell intervention during opening causes
the motor to stop until it is released
5. edge
EDGE TEST INACTIVE
The edge operation test is not
performed
EDGE TEST ACTIVE
Each time the main control unit receives an
open or close command, the EGDE TEST verifies
the edge is operating correctly.
If the test fails, the
edge
LED flashes at 2 Hz for
5 seconds, together with the
motor/test/error
LED.
During the TEST, the main control unit also
recognises whether the edge provides a
normally closed contract or an impedance
(conductive rubber edge).
PLEASE NOTE: if a conductive rubber edge
is used, it is essential to activate the EDGE
TEST, as otherwise the edge is not
recognised.