ENGLISH
- 47 -
11 - READING OF CYCLE COUNTER
KB1 control unit counts the completed opening cycles of the gate
and, if requested, it shows that service is required after a fixed
number of cycles.
There are two counters available:
• A totalizing counter for completed opening cycles thatcannot
be zeroed (option
tot
of item
Cont
)
• A downward counter for the number of cycles before the next
request for service (option
SErv
of item
Cont
).
• Event counter (
EvEn
option, see chapter 12)
To access the menu follow these instructions:
1.
Press and hold down the MENU key until the
-Cnt
appears
on the display
2.
Release the MENU key: the display will show
tot
The scheme hereafter shows how to read the totalizing counter,
how to read the number of cycles before the next service is
required as well as how to program the number of cycles before
the next request for service (as for the example shown, the control
unit completed no. 12451 cycles and there are no. 1300 cycles
before the next service request.
Area 1
is the reading of the total number of completed cycles;
through
h
and
i
keys, you can alternate the display of thousands
or units.
Area 2
is the reading of the number of cycles before the next
request for service: its value is rounded down to the hundreds.
Area 3
is the setup of this latter counter; on first pressing the
h
or
i
key the current value of the counter is rounded to the
thousand, each press after this increases the setting by 1000 units
or decreases by 100. The previous displayed count will get lost.
11.1 - SIGNAL OF SERVICE REQUIRED
As soon as the counter of cycles before the next request for
service is zero, the control unit shows the request for service
through an additional 5-second pre-blinking.
This signal will be repeated at each opening cycle, until the
installer enters into the counter reading and setup menu, and
possibly programs the number of cycles after which the next
service will be requested.
In case no new value is setup (that is to say that the counter value
is left at zero), the signalling function for the service request will
be disabled and no signal will be repeated anymore.
m
WARNING: service operations shall be carried out by
qualified staff only.
3
2
-Cnt
tot
SEru
EvEn
ESC
-01.3
-02.0
-01.0
-03.0
1
0 12.
.45 1
Summary of Contents for AYROS
Page 30: ...ITALIANO 28 ...
Page 32: ...ITALIANO 30 ...
Page 60: ...ENGLISH 58 ...
Page 62: ...ENGLISH 60 ...
Page 90: ...FRANÇAIS 88 ...
Page 92: ...FRANÇAIS 90 ...
Page 120: ...ESPAÑOL 118 ...
Page 122: ...ESPAÑOL 120 ...
Page 150: ... 148 PORTUGUÊS ...
Page 152: ... 150 PORTUGUÊS ...
Page 180: ...DEUTSCH 178 ...
Page 182: ...DEUTSCH 180 ...
Page 210: ...NEDERLANDS 208 ...
Page 212: ...NEDERLANDS 210 ...
Page 240: ... 238 POLSKI ...
Page 242: ...POLSKI ...
Page 243: ......