ENGLISH
10
RADIO CHANNEL CONFIGURATION
When the network is not configured, the base unit monitors the 16 possible radio channels and registers activity present in the
environment; for establishment of a new network, it is appropriate to select a channel on which there is low radio activity, in order to
avoid interference.
Set dip-switch 8 to ON: the green and red LEDs indicate the quality of the channel selected:
-
red LED:
unusable channel
-
green LED:
single flash - medium quality
double flash – good quality
triple flash – best channel
Alter dip-switches 3 to 6 in order to change the radio channel until the best channel is identified.
PLEASE NOTE: Once the channel is selected, return dip-switch 8 to OFF
PLEASE NOTE: The channel cannot be modified after the network has been configured.
If dip-switches 3 to 6 are altered with the network configured, the red LED will emit a series of flashes in fours.
RESET BASE UNIT CONFIGURATION
To delete the configuration of a base, it is necessary to press and hold the PROG button on the base unit until the red LED starts to flash.
Then release the button and repeat the radio channel configuration.
ASSOCIATING THE SENSOR WITH THE BASE
During association, the sensor communicates the installed configuration to the base.
NOTE: if a sensor is not connected to any edge, it cannot be associated with a base.
CAUTION: make sure edges are connected properly to the sensors prior to proceeding.
When association is complete, it is no longer possible to alter the sensor connections.
Install the sensors by following the instructions attached to the product, then proceed as follows:
To associate an edge with
unit 1
, proceed as follows:
1.
Press the PROG button on the base unit once: the ALARM LED emits single flashes
2.
Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3.
The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
To associate an edge with
unit 2
, proceed as follows:
1.
Press the PROG button on the base unit twice: the ALARM LED emits dual flashes
2.
Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3.
The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
To associate an edge with
both units
, proceed as follows:
1.
Press the PROG button on the base unit 3 times: the ALARM LED emits triple flashes
2.
Press and hold the sensor SET button until LED L3 flashes intensely and regularly, then release the button.
3.
The base automatically exits acquisition mode and the sensor starts to transmit with a period of 15 seconds
PLEASE NOTE:
Association must be completed within 15 seconds, otherwise the base unit exits acquisition mode.
4.
On completion, close the sensor casing and tighten the screws once more.
5.
Repeat the operation for the other sensors in the network. When all the sensors have been installed and associated,
close the base unit casing.
EDGE TESTING
Activate the base unit testing method by setting dip-switch 8 to ON. Press the edge to verify that:
1.
the LED on the sensor remains fixed and on
2.
the red (OUT1/OUT2) LED on the base unit comes on
3.
The control unit recognises the alarm on the input where the output from the u
PLEASE NOTE: Remember to return dip-switch 8 to OFF on completion of the test.