PROGRAMMING
34
when the photocells work again,the
gate stops for a time to be set
between 0 to 120 seconds.
Set the wished functions pressing the UP or
DOWN keys.
Press the MENU key to confirm.
If the function is t.PCh, the display shows:
Press the button UP or DOWN to program
the whished time.
Press the MENU key to confirm, on the
display will appear: Ft.PA.
If the function is rPAU, on the display will
appear: Ft.PA.
AUTOMATIC CLOSING
Permits the selection between the
semiautomatic or automatic functioning. By
the semiautomatic functioning the command
of START or PEDESTRIAN START opens
the gate, when the opening is complete the
gate remains still until the successive
command of opening, which will reclose it.
On the other hand, it stops automatically and
remains in pause phase for the set time
(t.PAU), then it closes again through the set
closing time. If the cycle is started with a
START, the control unit ignores the
command START P. until the end of the
cycle. The in pause time is adjusted from 0
to 999 seconds.
Press the MENU key to confirm, on the
display will appear:
Press the MENU key,the display shows one
of the 2 writings:
no
the automatic reclosing is not
available, the gate is semiautomatic.
t.PAU
the reclosing is available, the
standstill time is set from 0 to 999.
Set the wished functions pressing the UP or
DOWN keys.
Press the MENU key to confirm
If the function is t.PAU, the display shows:
Set the wished time pressing the UP or
DOWN keys.
Press the MENU key to confirm, on the
display will appear Ch.AU.
If the function is no, on the display will
appear: Ch.AU.
IMPORTANT: If the automatic reclosing is
not available, it is necessary to have the
command START in PAUSE menu St.PA).
COURTESY LIGHTS
Thanks to the connection "warning light" the
GB
PROGRAMMING
35
PD2 control unit enables the connection of
the courtesy lights (I.E. garden lights), which
can work automatically (lights on for the
whole cycle) or timed (lights on for a time
adjustable from 0 to 999 seconds). The lights
turn on with a START or PEDESTRIAN
START control. It is also possible to control
this connection using the code memorized in
the radio input tEL4, in this last case the
connection "warning light" becomes an
auxiliary connection to which it is possible
to match one of the following functional
logics:
monostable: it activates the output relay
through all the tx transmission time, when
the transmission ends the relay is
disconnected.
bistable:
it activates the relay with the tx first
transmission, the relay disconnects with the
second transmission.
timer: the tx transnission triggers the relay
which disconnects automatically after a time
adjustable between 0 and 999 seconds.
Press the keys UP or DOWN until the display
shows:
Press the MENU key,the display shows one
of the 3 writings:
t.LUC the courtesy lights start from a time
adjustable from 0 to 999 seconds.
CiCL
the courtesy lights are on through
the whole cycle.
AUS
auxiliary exit with adjustable logical
functioning.
Set the wished functions pressing the UP or
DOWN keys.
Press the MENU key to confirm
If the function selected is AUX, one of the
following will appear on the display:
tiM
timed auxiliary exit (time adjustable
from 0 to 999 seconds)
biSt
auxiliary output relay with bistable
functioning
Mon
auxiliary output relay with
monostable functioning
Press the UP or DOWN keys to select the
wished function.
Press the MENU key to confirm.
If the selected function is tiM, on the display
will appear:
Press the UP or DOWN keys to select the
wished time.
Press the MENU key to confirm, on the
display will appear: LUCi.
If the selected function is biST or Mon on
the display will appear
LUCi.
If the function is t.LUC, on the display will
appear:
Press the UP or DOWN keys to select the
wished time.
GB