Installation instructions

Built-in variants of gas hob

GAS731

1094429-04

26/07/2023

1094429-04

1

The appliance must be installed by qualified personnel only. Each step must be carried out and checked in full in the
order specified.

Check that the local connection conditions (gas type and gas pressure) and the appliance setting match before con-
necting the appliance.

The default values for this appliance are provided on the information plate (or on the identification plate).

This appliance is not connected to a combustion by-product outlet. It must be set up and connected according to the
applicable installation conditions. Particular attention must be paid to the relevant ventilation requirements.

If installing into a combustible material, the guidelines and standards for low-voltage installations and fire protection
must be strictly observed.

All leak tests should be done with a soapy water solution. Never use an open flame to check for leaks!

Validity

These installation instructions apply to the following models:

Model designation

Model number

Type

Appliance class

GAS731GK

31075

GAS731GKBZ

Class 3 

DIN EN 30-1-1

General notes

Identification plate

The identification plate and stickers with the permissible
gas types and safety precautions are located on the under-
side of the hob.

Identification plate

Depending on 
appliance, plate 
with additional 
information

Affix the second identification plate (supplied) in an accessible position behind the front of the fitted cabinet beneath the appliance.

Care and maintenance

Follow the care and cleaning advice in the operating instructions.

Follow the basic maintenance advice in the operating instructions.

Summary of Contents for GAS731 Series

Page 1: ...tible material the guidelines and standards for low voltage installations and fire protection must be strictly observed All leak tests should be done with a soapy water solution Never use an open flame to check for leaks Validity These installation instructions apply to the following models Model designation Model number Type Appliance class GAS731GK 31075 GAS731GKBZ Class 3 DIN EN 30 1 1 General ...

Page 2: ...e surface mounted combination of several hobs 1019199 Flush installation Designation Art no Steel angle set hob size 70 H63773 Designation Art no Instant adhesive for installation of the steel angle 50 ml B11657 Straight mixing nozzle B11656 TREMCLEAN isopropyl alcohol 1000 ml 1056609 Black silicone FA880 310 ml B11555 Anthracite silicone FA880 310 ml B11556 White silicone FA880 310 ml 1031313 Sto...

Page 3: ... appliance for base plate Ra Outer corner radii of cut out S Minimum distance between the top of the work surfaces and any drawer T Minimum distance between the cut out in the back and any drawer Installation Do not damage the sealing bead The sealing bead must lie all around the edge of worktop Create an accurate installation cut out Carefully put the appliance in the installation cut out and pre...

Page 4: ...tween the cut out in the back and any drawer Installation Create an accurate installation cut out The mounting surface can be reamed out or created by installing wood stone supports or using the steel angle set see Ac cessories Access to the appliance from below via the entire cut out area must be guaranteed For servicing purposes the appliance base can be removed from below Prepare the cut out an...

Page 5: ...onnection cable has either a plug or three stranded wires Plug in appliances must be connected to an easily accessible power socket Appliances with stranded wires must be connected by a qualified electrician via a junction box according to local regulations Installation pipe Distribution box Clamp The mains plug must not be cut off Ventilation In order to guarantee minimum ventilation a space of 2...

Page 6: ...de of over 2 000 metres a reduced performance must be expected Gas connection The gas connection and the conversion to another gas type must be carried out by an authorized installer 51 46 22 4 G ISO 228 1 GAS731 65 The gas connection must be positioned so that the stop cock and the supply connection point are accessible with the appliance in stalled The gas connection must be positioned so that i...

Page 7: ...ditional nozzle sets available for country specific combinations of gas type and connection pressure Liquid gas G30 50 mbar Natural gas L K G25 G25 3 25 mbar Natural gas G20 13 mbar Natural gas G20 25 mbar GAS731GKBZ Natural gas H E G20 20 mbar Liquid gas butane propane G30 31 28 30 37 mbar Nozzle set 1015475 Nozzle set 1015476 Nozzle set 1015478 Nozzle set 1015477 All the nozzles are numbered to ...

Page 8: ... position for each burner Nozzle table Change injector nozzles using a 7 inch socket wrench or corresponding wrench For the appliance the following gas types are available Gas type Test gas Connection pressure Injector nozzles ø in hundredths of a mm Wok burner Standard burner Rapid burner A inside B inside A outside B outside A B A B Natural gas H E G20 20 mbar 71 42 2 125 82 97 48 125 63 Liquid ...