background image

Installation instructions

Range hood
Operating modes: Extraction/recirculation
DWPQ9, DWPQ12

1039460-R01

13/12/2017

1039460-R01

1

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

Validity

These installation instructions apply to:

62022

 (DWPQ9, construction width 90 cm)

62023

 (DWPQ12, construction width 120 cm)

General notes

If other firing systems are being used at the same time (e.g. wood, gas, oil or coal fired heating appliances), safe op-
eration is only possible providing a room negative pressure of 4 Pa (0.04 mbar) is not exceeded at the location of the
appliance.
Risk of toxic fumes! An adequate flow of fresh air must be guaranteed e.g. via non-closable openings in doors or
windows and in combination with an air-intake/exhaust-air wall box or by other technical means.

If the appliance is installed over hobs, each cooking zone must be fitted with an ignition fuse and the minimum dis-
tances (see section «Dimensions») must be adhered to.

Efficient repairs can only be guaranteed if it is possible to uninstall the complete appliance at any time without caus-
ing any damage.

Identification plate

Remove the grease filters. The identification plate is located on the inside of the appliance.

Installation accessories supplied

All fixing elements are contained in the scope of delivery.

2 × bolt anchors 

BA

 (ø6 × 30 mm)

2 × collar nuts 

G

 (M6)

6 × rawlplugs 

DL

 (ø8 × 40 mm)

2 × screws 

S3

 (M4 ×10 mm)

6 × screws 

S5/S6/S7

 (ø5 × 40 mm)

2 × dummy covers 

D

2 × screws 

S6

 (M4 ×20 mm)

2 × screws 

S10

 (ø3.5 × 6 mm)

Extraction mode

The extracted air must not be fed into a chimney which is used for exhausting fumes from appliances burning gas or
other fuels.
Observe the local fire regulations.

Recirculation mode

If an exhaust air connection is not structurally possible, the range hood must be set up for recirculation operation. There is the following
possibility to do this:

Using an activated charcoal filter unit directly in the appliance.

The cross-sectional area (air outlet area) of the ventilation grille must be at least 200 cm

2

.

Accessories

Product

Article no.

Remote control

1046973

Starter set for long-life-Plus activated charcoal filter

1046969