15.2 Mounting the cabinet front(s)
When installing, note:
- Cabinet front must be installed symmetrically to the
refrigerator door.
- Adjoining cabinet front is exactly level.
- Adjoining cabinet front has the same edge radius as the
front of the appliance.
- Cabinet front is flat and tension-free.
- Cabinet front is adjusted to a minimum depth of approx.
2 mm to the unit body.
u
Fit the appliance into the recess .
u
Attach the cabinet front to the appliance door .
u
Check the cabinet front does not collide with anything
(see 15.3 Setting the clearance to avoid collision) .
15.3 Setting the clearance to avoid colli‐
sion
After installing the cabinet front(s), check that the cabinet
fronts do not collide.
Fig. 67
(1) Front thickness (FD)
(3) Clearance (S)
(2) Edge radius (R)
Fig. 68 Table of clearance limits
G
min
= min. clearance in mm
G
max
= max. clearance in mm
Note
When making adjustments, always make sure that the
cabinet front suits the general appearance.
Check the collision factors and adjust them accordingly:
u
Determine the front thickness and edge radius.
u
Refer to the table for the min./max. clearance dimen‐
sions.
u
Check the clearance size against the table.
u
Do one of the following depending on the measured
clearance size.
Clearance
Description
S > G
max
If the clearance size is greater than the two
limits, you do not need to make any adjust‐
ments.
S < G
min
If the clearance size is below the limits,
you must increase it. Another option is to
increase the edge radius.
G
min
≤ S ≤
G
max
If the clearance is between the two limits,
you have to be careful. This will quickly
lead to collisions.
16 Connecting device
WARNING
Failure to connect properly
Fire hazard.
u
Do not use an extension cable.
u
Do not use distributor blocks.
NOTICE
Failure to connect properly
Damage to the electronics.
u
Do not connect the appliance to a stand-alone inverter,
e.g. solar power systems and petrol generators.
u
Do not use an energy saving plug.
Note
Only use the supplied mains cable.
u
A longer mains cable can be ordered from Customer
Service.
Ensure that the following conditions are met:
- The type of current and voltage at the installation site
match the information on the serial tag .
- The socket is earthed according to the regulations and
fused.
- The fuse tripping current is between 10 and 16 A.
- The socket is easily accessible.
u
Check the electrical connection.
u
Connect the mains plug to the power supply.
w
V-ZUG logo appears on the screen.
w
The display switches to the standby symbol.
Connecting device
* Depending on model and options
63